Lupum venalitii Copper/Aluminium XLPE Type Power Cable Structure Power Supple Cable

Description:

0.6/1kv Xlpe insulata Pvc vaginatus aluminium funem potentiae adhibentur ad distributionem potestatis in stationibus potentiae, institutionis industrialis et switchgears, necnon in locis mains.Tractationem in institutione certa ferre possunt.Ad certam institutionem sub terra.

 

 

Acceptatio: OEM/ODM, Trade, Tutus, Regionalis Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

Clavis ad successum nostrum est "Bona Solutio Top qualitas, valor rationis et muneris efficientis" pro Tutus Dealers of Copper/Aluminium XLPE Type Power Cable Structure Power Supple Cable, Praeter, negotia nostra haeret ad bonam qualitatem et realitatem rate, et nos etiam donamus. fantastic OEM suggero ut satis paucae notae celebres.
Clavis ad successum nostrum est "Solutio Bonus Top qualitas, Rationabilis Valor et Effectus Muneris" proChina Cable Copper Cable 4core Cable and Electric Power CableHodiernae clientes sumus ex toto orbe, incluso USA, Russia, Hispania, Italia, Singapore, Malaysia, Thailandia, Polonia, Irania et Iraquia.Societas nostra missio est summa qualitas productorum optimo pretio providere.Weve've been looking forward to doing business with you.

Applicationem

Adhibentur in domesticis, in cuniculo vel funiculo fossae, rudentes non armatae, quae vires mechanicas externas ferre non possunt.

Construction

AVAV

Characteres

Rated voltage 0.6/1kV
Conductor aluminium
Insulation XLPE
Vagina PVC
Core 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Color Nigrum vel nativus

Signa

GB/T 12706、IEC、BS、DIN et ICEA postulante

Morbi laoreet

2 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

2×4

0.7

1.8

11.4

150

7.41

3.5

34

45

2×6

0.7

1.8

12.4

171

4.61

3.5

43

57

2×10

0.7

1.8

14.9

238

3.08

3.5

60

77

2×16

0.7

1.8

17.1

294

1.91

3.5

83

105

2×25

0.9

1.8

20

394

1.2

3.5

105

125

2×35

0.9

1.8

22

484

0.868

3.5

125

155

2×50

1

1.8

23.4

497

0.641

3.5

160

185

2×70

1.1

1.8

24.5

640

0.443

3.5

200

225

2×95

1.1

1.9

28.6

827

0.32

3.5

245

270

2×120

1.2

2

29.7

1015

0.253

3.5

285

310

2×150

1.4

2.2

31.2

1268

0.206

3.5

325

345

3 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4

0.7

1.8

12

163

7.41

3.5

34

45

3×6

0.7

1.8

13

191

4.61

3.5

43

57

3×10

0.7

1.8

15.8

282

3.08

3.5

60

77

3×16

0.7

1.8

18.2

358

1.91

3.5

83

105

3×25

0.9

1.8

21.3

491

1.2

3.5

105

125

3×35

0.9

1.8

23.6

600

0.868

3.5

125

155

3×50

1

1.8

23.8

729

0.641

3.5

160

185

3×70

1.1

1.9

27.4

958

0.443

3.5

200

225

3×95

1.1

2

33.1

1242

0.32

3.5

245

270

3×120

1.2

2.1

34.7

1502

0.253

3.5

285

310

3×150

1.4

2.3

39.1

1875

0.206

3.5

325

345

3× 185

1.6

2.4

42.3

2264

0.164

3.5

375

390

3×240

1.7

2.6

47.8

2861

0.125

3.5

440

450

3×300

1.8

2.8

52.4

3501

0.1

3.5

505

515

3×400

2

3.1

62.9

4627

0.0078

3.5

570

575

4 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4

0.7

1.8

13

197

7.41

3.5

34

45

4×6

0.7

1.8

14.2

233

4.61

3.5

43

57

4×10

0.7

1.8

17.2

345

3.08

3.5

60

77

4×16

0.7

1.8

19.9

442

1.91

3.5

83

105

4×25

0.9

1.8

23.4

595

1.2

3.5

105

125

4×35

0.9

1.8

25.8

734

0.868

3.5

125

155

4×50

1

1.9

27.2

912

0.641

3.5

160

185

4×70

1.1

2

27.9

1207

0.443

3.5

200

225

4×95

1.1

2.1

33.8

1569

0.32

3.5

245

270

4×120

1.2

2.3

35.8

1923

0.253

3.5

285

310

4×150

1.4

2.4

40.2

2374

0.206

3.5

325

345

4× 185

1.6

2.6

43.6

2899

0.164

3.5

375

390

4×240

1.7

2.8

49.3

3670

0.125

3.5

440

450

4×300

1.8

3

54.1

4499

0.1

3.5

505

515

4×400

2

3.3

65.1

5947

0.0078

3.5

570

575

5 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

5×4

0.7

1.8

14

223

7.41

3.5

34

45

5×6

0.7

1.8

15.3

266

4.61

3.5

43

57

5×10

0.7

1.8

18.7

395

3.08

3.5

60

77

5×16

0.7

1.8

21.7

512

1.91

3.5

83

105

5×25

0.9

1.8

25.6

700

1.2

3.5

105

125

5×35

0.9

1.8

28.3

872

0.868

3.5

125

155

5×50

1

2

31.6

1155

0.641

3.5

160

185

5×70

1.1

2.1

37.2

1536

0.443

3.5

200

225

5×95

1.1

2.3

41

1971

0.32

3.5

245

270

5×120

1.2

2.4

46.2

2430

0.253

3.5

285

310

5×150

1.4

2.6

50.8

3036

0.206

3.5

325

345

5× 185

1.6

2.8

56.6

3716

0.164

3.5

375

390

5×240

1.7

3

62.8

4677

0.125

3.5

440

450

5×300

1.8

3.2

71.4

5758

0.1

3.5

505

515

3+1 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 1×2.5

0.7

1.8

12.7

189

7.41

3.5

34

45

3×6 + 1×4

0.7

1.8

13.9

224

4.61

3.5

43

57

3×10 + 1×6

0.7

1.8

16.4

311

3.08

3.5

60

77

3×16 + 1×10

0.7

1.8

19.2

418

1.91

3.5

83

105

3×25 + 1×16

0.9

1.8

22.5

557

1.2

3.5

105

125

3×35 + 1×16

0.9

1.8

25

667

0.868

3.5

125

155

3×50 + 1×25

1

1.8

25.5

833

0.641

3.5

160

185

3×70 + 1×35

1.1

1.9

28.9

1096

0.443

3.5

200

225

3×95 + 1×50

1.1

2.1

35.3

1448

0.32

3.5

245

270

3×120 + 1×70

1.2

2.2

37.1

1787

0.253

3.5

285

310

3×150 + 1×70

1.4

2.3

41.7

2143

0.206

3.5

325

345

3×185 + 1×95

1.6

2.5

45.3

2629

0.164

3.5

375

390

3×240 + 1×120

1.7

2.7

51.3

3314

0.125

3.5

440

450

3×300 + 1×150

1.8

2.9

56.3

4062

0.1

3.5

505

515

3×400 + 1×240

2

3.1

67.6

5295

0.0078

3.5

570

575

3+2 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 2×2.5

0.7

1.8

13.5

208

7.41

3.5

34

45

3×6 + 2×4

0.7

1.8

14.8

249

4.61

3.5

43

57

3×10 + 2×6

0.7

1.8

17.4

343

3.08

3.5

60

77

3×16 + 2×10

0.7

1.8

20.5

465

1.91

3.5

83

105

3×25 + 2×16

0.9

1.8

24

625

1.2

3.5

105

125

3×35 + 2×16

0.9

1.8

25.7

728

0.868

3.5

125

155

3×50 + 2×35

1

1.9

29

980

0.641

3.5

160

185

3×70 + 2×35

1.1

2

33.8

1284

0.443

3.5

200

225

3×95 + 2×50

1.1

2.2

37.4

1660

0.32

3.5

245

270

3×120 + 2×70

1.2

2.3

42.8

2089

0.253

3.5

285

310

3×150 + 2×70

1.4

2.4

45.2

2424

0.206

3.5

325

345

3×185 + 2×95

1.6

2.6

50.6

3010

0.164

3.5

375

390

3×240 + 2×120

1.7

2.8

56

3772

0.125

3.5

440

450

3×300 + 2×150

1.8

3

64.6

4673

0.1

3.5

505

515

4+1 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×6 + 1×4

0.7

1.8

15

259

4.61

3.5

43

57

4×10 + 1×6

0.7

1.8

17.7

364

3.08

3.5

60

77

4×16 + 1×10

0.7

1.8

20.3

490

1.91

3.5

83

105

4×25 + 1×16

0.9

1.8

24.2

665

1.2

3.5

105

125

4×35 + 1×16

0.9

1.8

26.4

803

0.868

3.5

125

155

4×50 + 1×25

1

1.9

32.6

1114

0.641

3.5

160

185

4×70 + 1×35

1.1

2.1

37.4

1806

0.443

3.5

200

225

4×95 + 1×50

1.1

2.2

42.4

2211

0.32

3.5

245

270

4×120 + 1×70

1.2

2.4

47.9

2677

0.253

3.5

285

310

4×150 + 1×70

1.4

2.5

51.9

3135

0.206

3.5

325

345

4×185 + 1×95

1.6

2.7

58

4038

0.164

3.5

375

390

4×240 + 1×120

1.7

2.9

65.1

4919

0.125

3.5

440

450

4×300 + 1×150

1.8

3.1

72

5957

0.1

3.5

505

515

包装 与 运输Clavis ad successum nostrum est "Bona Solutio Top qualitas, valor rationis et muneris efficientis" pro Tutus Dealers of Copper/Aluminium XLPE Type Power Cable Structure Power Supple Cable, Praeter, negotia nostra haeret ad bonam qualitatem et realitatem rate, et nos etiam donamus. fantastic OEM suggero ut satis paucae notae celebres.
Lupum venalitiiChina Cable Copper Cable 4core Cable and Electric Power CableHodiernae clientes sumus ex toto orbe, incluso USA, Russia, Hispania, Italia, Singapore, Malaysia, Thailandia, Polonia, Irania et Iraquia.Societas nostra missio est summa qualitas productorum optimo pretio providere.Weve've been looking forward to doing business with you.