Vestibulum Companies pro 1kv, 11kv, 35kv XLPE Insulation Steel Wire Armored Electric Cable
Inhaerentes opinioni vestrae "solutiones creandi qualitates et amiculos generantes cum hominibus ex omnibus circa mundum", semper tenemus clientium fascinationem incipere cum societatibus pro 1kv, 11kv, 35kv, 35kv XLPE Insulation Steel Wire Armored Electric Cable, Inceptum nostrum operatur ab operatione principii "integritatis fundatae, cooperatio creata, homines ordinati, cooperationem vincere".Speramus nos iucundam Romanorum negotiatorem ex toto orbe terrarum habere posse.
Adhaerentes opinioni vestrae "Creando solutiones qualitates optimas et amiculos generantes cum hominibus ex omnibus circa mundum", semper nos e clientibus allicientibus ut incipiamus.China 1kv Electric Cable and 11kv Electric CableNoster website domesticus supra 50, 000 ordines emendos quotannis generavit ac satis prospere pro interrete shopping in Iaponia generavit.Nos laeti esse volumus occasionem negotii cum societate tua agendi.Exspecto accepto tuo!
Applicationem
Filum chalybeis cables armatae vel SWA cables est funis indutus durus ex Vagina Niger PVC, xlpe velit, conductores aeris et filum ferreum armatura.SWA Cables principales ad electricitatem destinatur ad retia subterranea, potestates retiaculorum ponenda, principalia ad domos advenientes inter multitudinem aliarum applicationum externe et interne.
Construction
Characteres
Conductor: Aluminium vel Copper
CATAFRACTATUS: SWA (Steel Wire Armoured)
Nulla: XLPE (polyethylene crucis coniunctum) aestimavit XC ° C
Cores: 1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Sectio Area: 1.5mm2-300mm2
Packaging: Iron aut ligneus Drum
Signa
IEC 60502, BS 7870, GB/T12706
Morbi laoreet
2 Core Steel Wire Armored Cable | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Diae.Armatura filum | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
2×1.5 | 0.7 | 1 | 0.9 | 1.8 | 15 | 330 | 12.1 | 3.5 | 20 | 27 |
2×2.5 | 0.7 | 1 | 0.9 | 1.8 | 16 | 376 | 7.41 | 3.5 | 26 | 35 |
2×4 | 0.7 | 1 | 0.9 | 1.8 | 17 | 554 | 4.61 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1 | 0.9 | 1.8 | 18.2 | 633 | 3.08 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1 | 1.25 | 1.8 | 21 | 797 | 1.83 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1 | 1.6 | 1.8 | 23.5 | 1124 | 1.15 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1 | 1.6 | 1.8 | 26 | 1417 | 0.727 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1 | 1.6 | 1.8 | 30.5 | 1694 | 0.524 | 3.5 | 125 | 155 |
2×50 | 1 | 1 | 1.6 | 1.8 | 27 | 1787 | 0.387 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1 | 1.6 | 2 | 30 | 2181 | 0.268 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.2 | 1.6 | 2.1 | 34 | 2768 | 0.193 | 3.5 | 245 | 270 |
2×120 | 1.2 | 1.2 | 2 | 2.2 | 36.5 | 3500 | 0.153 | 3.5 | 285 | 310 |
2×150 | 1.4 | 1.2 | 2 | 2.4 | 42 | 4233 | 0.124 | 3.5 | 325 | 345 |
2×185 | 1.2 | 2 | 2.5 | 45 | 4979 | 0.0991 | 3.5 | 375 | 390 |
3 Core Steel Wire Armored Cable | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Diae.Armatura filum | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×1.5 | 0.7 | 1 | 0.9 | 1.8 | 15.8 | 359 | 12.1 | 3.5 | 20 | 27 |
3×2.5 | 0.7 | 1 | 0.9 | 1.8 | 16.8 | 415 | 7.41 | 3.5 | 26 | 35 |
3×4 | 0.7 | 1 | 0.9 | 1.8 | 18 | 611 | 4.61 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1 | 0.9 | 1.8 | 19 | 718 | 3.08 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1 | 1.25 | 1.8 | 22 | 937 | 1.83 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1 | 1.6 | 1.8 | 24.5 | 1318 | 1.15 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1 | 1.6 | 1.8 | 29.2 | 1707 | 0.727 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1 | 1.6 | 1.8 | 32.5 | 2071 | 0.524 | 3.5 | 125 | 155 |
3×50 | 1 | 1 | 1.6 | 1.9 | 33 | 2405 | 0.387 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1 | 1.6 | 2 | 37 | 3084 | 0.268 | 3.5 | 200 | 225 |
3×95 | 1.1 | 1.2 | 1.6 | 2.1 | 43 | 4126 | 0.193 | 3.5 | 245 | 270 |
3×120 | 1.2 | 1.2 | 2 | 2.3 | 45 | 4901 | 0.153 | 3.5 | 285 | 310 |
3×150 | 1.4 | 1.4 | 2 | 2.4 | 51 | 6365 | 0.124 | 3.5 | 325 | 345 |
3× 185 | 1.6 | 1.4 | 2 | 2.6 | 56 | 7555 | 0.0991 | 3.5 | 375 | 390 |
3×240 | 1.7 | 1.4 | 2.5 | 2.8 | 62 | 9284 | 0.093 | 3.5 | 440 | 450 |
3×300 | 1.8 | 1.6 | 2.5 | 3 | 67 | 11226 | 0.093 | 3.5 | 505 | 515 |
3×400 | 2 | 1.6 | 2.5 | 3.2 | 74 | 15714 | 0.047 | 3.5 | 570 | 575 |
4 Core Steel Wire Armored Cable | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Diae.Armatura filum | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 | 0.7 | 1 | 0.9 | 1.8 | 18 | 699 | 4.61 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1 | 1.25 | 1.8 | 19 | 820 | 3.08 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1 | 1.25 | 1.8 | 22 | 1233 | 1.83 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1 | 1.6 | 1.8 | 24.5 | 1550 | 1.15 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1 | 1.6 | 1.8 | 29.2 | 2036 | 0.727 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1 | 2 | 1.9 | 32.5 | 2501 | 0.524 | 3.5 | 125 | 155 |
4×50 | 1 | 1 | 2 | 2 | 33 | 3064 | 0.387 | 3.5 | 160 | 185 |
4×70 | 1.1 | 1 | 2 | 2.1 | 37 | 3974 | 0.268 | 3.5 | 200 | 225 |
4×95 | 1.1 | 1.2 | 2 | 2.3 | 43 | 5032 | 0.193 | 3.5 | 245 | 270 |
4×120 | 1.2 | 1.2 | 2.5 | 2.4 | 45 | 6327 | 0.153 | 3.5 | 285 | 310 |
4×150 | 1.4 | 1.4 | 2.5 | 2.5 | 51 | 7765 | 0.124 | 3.5 | 325 | 345 |
4× 185 | 1.6 | 1.4 | 2.5 | 2.7 | 56 | 9205 | 0.0991 | 3.5 | 375 | 390 |
4×240 | 1.7 | 1.4 | 2.5 | 3 | 62 | 11444 | 0.093 | 3.5 | 440 | 450 |
4×300 | 1.8 | 1.6 | 2.5 | 3.2 | 67 | 13830 | 0.093 | 3.5 | 505 | 515 |
4×400 | 2 | 1.6 | 3.15 | 3.5 | 74 | 19673 | 0.047 | 3.5 | 570 | 575 |
Inhaerentes opinioni vestrae "solutiones creandi qualitates et amiculos generantes cum hominibus ex omnibus circa mundum", semper tenemus clientium fascinationem incipere cum societatibus pro 1kv, 11kv, 35kv, 35kv XLPE Insulation Steel Wire Armored Electric Cable, Inceptum nostrum operatur ab operatione principii "integritatis fundatae, cooperatio creata, homines ordinati, cooperationem vincere".Speramus nos iucundam Romanorum negotiatorem ex toto orbe terrarum habere posse.