Dum "Client-Oriented" philosophia usus est, summus qualitas administrationis methodi flagitat, productos innovans et etiam validos R&D vis laboris, semper libera merces qualitatis, solutiones superbas et incrementa pretia venditionis bonae qualitatis 0.6/1kv Low intentione Sub Copper/Aluminium Conductor XLPE Insulatus PVC Ferro Wire Armored Power Cable circumdedit, Societas nostra amice ex toto orbe benigne excipitur ad negotium visitandum, inquirendum et tractandum.
Dum philosophiam "Client-Oriented" comitatu utens, summus qualitas administrationis methodi flagitans, productiones novas producendi ac etiam validam operarum R&D, semper liberam mercium qualitatem, solutiones superbas et incrementa pretia venditionis trademus.Sina Cable et Electric CableProspicientes optimas rationes et solutiones, perfectissimum ministerium cum aequissimis pretiis principia nostra sunt.Nos quoque OEM et ODM ordines recipimus. Dedicati severae qualitati moderatio et curiosi servitii emptoris, praesto sumus semper ad de tuis postulatis disserere et plenam satisfactionem emptoris impendere.Amicos nobis sincere suscipimus ut ad negotia paciscenda veniamus et cooperationem incipiamus.
Applicationem
Adhibentur in domesticis, in cuniculo vel funiculo fossae, rudentes non armatae, quae vires mechanicas externas ferre non possunt.
Construction
Characteres
Rated voltage | 0.6/1kV |
Conductor | aluminium |
Insulation | XLPE |
Vagina | PVC |
Core | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
Color | Nigrum vel nativus |
Signa
GB/T 12706、IEC、BS、DIN et ICEA postulante
Morbi laoreet
2 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
2×4 | 0.7 | 1.8 | 11.4 | 150 | 7.41 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.8 | 12.4 | 171 | 4.61 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.8 | 14.9 | 238 | 3.08 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.8 | 17.1 | 294 | 1.91 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.8 | 20 | 394 | 1.2 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.8 | 22 | 484 | 0.868 | 3.5 | 125 | 155 |
2×50 | 1 | 1.8 | 23.4 | 497 | 0.641 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 24.5 | 640 | 0.443 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.9 | 28.6 | 827 | 0.32 | 3.5 | 245 | 270 |
2×120 | 1.2 | 2 | 29.7 | 1015 | 0.253 | 3.5 | 285 | 310 |
2×150 | 1.4 | 2.2 | 31.2 | 1268 | 0.206 | 3.5 | 325 | 345 |
3 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 | 0.7 | 1.8 | 12 | 163 | 7.41 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.8 | 13 | 191 | 4.61 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.8 | 15.8 | 282 | 3.08 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.8 | 18.2 | 358 | 1.91 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.8 | 21.3 | 491 | 1.2 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.8 | 23.6 | 600 | 0.868 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 23.8 | 729 | 0.641 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.9 | 27.4 | 958 | 0.443 | 3.5 | 200 | 225 |
3×95 | 1.1 | 2 | 33.1 | 1242 | 0.32 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2.1 | 34.7 | 1502 | 0.253 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2.3 | 39.1 | 1875 | 0.206 | 3.5 | 325 | 345 |
3× 185 | 1.6 | 2.4 | 42.3 | 2264 | 0.164 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.6 | 47.8 | 2861 | 0.125 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.8 | 52.4 | 3501 | 0.1 | 3.5 | 505 | 515 |
3×400 | 2 | 3.1 | 62.9 | 4627 | 0.0078 | 3.5 | 570 | 575 |
4 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 | 0.7 | 1.8 | 13 | 197 | 7.41 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 14.2 | 233 | 4.61 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 17.2 | 345 | 3.08 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 19.9 | 442 | 1.91 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 23.4 | 595 | 1.2 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 25.8 | 734 | 0.868 | 3.5 | 125 | 155 |
4×50 | 1 | 1.9 | 27.2 | 912 | 0.641 | 3.5 | 160 | 185 |
4×70 | 1.1 | 2 | 27.9 | 1207 | 0.443 | 3.5 | 200 | 225 |
4×95 | 1.1 | 2.1 | 33.8 | 1569 | 0.32 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2.3 | 35.8 | 1923 | 0.253 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.4 | 40.2 | 2374 | 0.206 | 3.5 | 325 | 345 |
4× 185 | 1.6 | 2.6 | 43.6 | 2899 | 0.164 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.8 | 49.3 | 3670 | 0.125 | 3.5 | 440 | 450 |
4×300 | 1.8 | 3 | 54.1 | 4499 | 0.1 | 3.5 | 505 | 515 |
4×400 | 2 | 3.3 | 65.1 | 5947 | 0.0078 | 3.5 | 570 | 575 |
5 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
5×4 | 0.7 | 1.8 | 14 | 223 | 7.41 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1.8 | 15.3 | 266 | 4.61 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1.8 | 18.7 | 395 | 3.08 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1.8 | 21.7 | 512 | 1.91 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1.8 | 25.6 | 700 | 1.2 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1.8 | 28.3 | 872 | 0.868 | 3.5 | 125 | 155 |
5×50 | 1 | 2 | 31.6 | 1155 | 0.641 | 3.5 | 160 | 185 |
5×70 | 1.1 | 2.1 | 37.2 | 1536 | 0.443 | 3.5 | 200 | 225 |
5×95 | 1.1 | 2.3 | 41 | 1971 | 0.32 | 3.5 | 245 | 270 |
5×120 | 1.2 | 2.4 | 46.2 | 2430 | 0.253 | 3.5 | 285 | 310 |
5×150 | 1.4 | 2.6 | 50.8 | 3036 | 0.206 | 3.5 | 325 | 345 |
5× 185 | 1.6 | 2.8 | 56.6 | 3716 | 0.164 | 3.5 | 375 | 390 |
5×240 | 1.7 | 3 | 62.8 | 4677 | 0.125 | 3.5 | 440 | 450 |
5×300 | 1.8 | 3.2 | 71.4 | 5758 | 0.1 | 3.5 | 505 | 515 |
3+1 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 1×2.5 | 0.7 | 1.8 | 12.7 | 189 | 7.41 | 3.5 | 34 | 45 |
3×6 + 1×4 | 0.7 | 1.8 | 13.9 | 224 | 4.61 | 3.5 | 43 | 57 |
3×10 + 1×6 | 0.7 | 1.8 | 16.4 | 311 | 3.08 | 3.5 | 60 | 77 |
3×16 + 1×10 | 0.7 | 1.8 | 19.2 | 418 | 1.91 | 3.5 | 83 | 105 |
3×25 + 1×16 | 0.9 | 1.8 | 22.5 | 557 | 1.2 | 3.5 | 105 | 125 |
3×35 + 1×16 | 0.9 | 1.8 | 25 | 667 | 0.868 | 3.5 | 125 | 155 |
3×50 + 1×25 | 1 | 1.8 | 25.5 | 833 | 0.641 | 3.5 | 160 | 185 |
3×70 + 1×35 | 1.1 | 1.9 | 28.9 | 1096 | 0.443 | 3.5 | 200 | 225 |
3×95 + 1×50 | 1.1 | 2.1 | 35.3 | 1448 | 0.32 | 3.5 | 245 | 270 |
3×120 + 1×70 | 1.2 | 2.2 | 37.1 | 1787 | 0.253 | 3.5 | 285 | 310 |
3×150 + 1×70 | 1.4 | 2.3 | 41.7 | 2143 | 0.206 | 3.5 | 325 | 345 |
3×185 + 1×95 | 1.6 | 2.5 | 45.3 | 2629 | 0.164 | 3.5 | 375 | 390 |
3×240 + 1×120 | 1.7 | 2.7 | 51.3 | 3314 | 0.125 | 3.5 | 440 | 450 |
3×300 + 1×150 | 1.8 | 2.9 | 56.3 | 4062 | 0.1 | 3.5 | 505 | 515 |
3×400 + 1×240 | 2 | 3.1 | 67.6 | 5295 | 0.0078 | 3.5 | 570 | 575 |
3+2 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 2×2.5 | 0.7 | 1.8 | 13.5 | 208 | 7.41 | 3.5 | 34 | 45 |
3×6 + 2×4 | 0.7 | 1.8 | 14.8 | 249 | 4.61 | 3.5 | 43 | 57 |
3×10 + 2×6 | 0.7 | 1.8 | 17.4 | 343 | 3.08 | 3.5 | 60 | 77 |
3×16 + 2×10 | 0.7 | 1.8 | 20.5 | 465 | 1.91 | 3.5 | 83 | 105 |
3×25 + 2×16 | 0.9 | 1.8 | 24 | 625 | 1.2 | 3.5 | 105 | 125 |
3×35 + 2×16 | 0.9 | 1.8 | 25.7 | 728 | 0.868 | 3.5 | 125 | 155 |
3×50 + 2×35 | 1 | 1.9 | 29 | 980 | 0.641 | 3.5 | 160 | 185 |
3×70 + 2×35 | 1.1 | 2 | 33.8 | 1284 | 0.443 | 3.5 | 200 | 225 |
3×95 + 2×50 | 1.1 | 2.2 | 37.4 | 1660 | 0.32 | 3.5 | 245 | 270 |
3×120 + 2×70 | 1.2 | 2.3 | 42.8 | 2089 | 0.253 | 3.5 | 285 | 310 |
3×150 + 2×70 | 1.4 | 2.4 | 45.2 | 2424 | 0.206 | 3.5 | 325 | 345 |
3×185 + 2×95 | 1.6 | 2.6 | 50.6 | 3010 | 0.164 | 3.5 | 375 | 390 |
3×240 + 2×120 | 1.7 | 2.8 | 56 | 3772 | 0.125 | 3.5 | 440 | 450 |
3×300 + 2×150 | 1.8 | 3 | 64.6 | 4673 | 0.1 | 3.5 | 505 | 515 |
4+1 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×6 + 1×4 | 0.7 | 1.8 | 15 | 259 | 4.61 | 3.5 | 43 | 57 |
4×10 + 1×6 | 0.7 | 1.8 | 17.7 | 364 | 3.08 | 3.5 | 60 | 77 |
4×16 + 1×10 | 0.7 | 1.8 | 20.3 | 490 | 1.91 | 3.5 | 83 | 105 |
4×25 + 1×16 | 0.9 | 1.8 | 24.2 | 665 | 1.2 | 3.5 | 105 | 125 |
4×35 + 1×16 | 0.9 | 1.8 | 26.4 | 803 | 0.868 | 3.5 | 125 | 155 |
4×50 + 1×25 | 1 | 1.9 | 32.6 | 1114 | 0.641 | 3.5 | 160 | 185 |
4×70 + 1×35 | 1.1 | 2.1 | 37.4 | 1806 | 0.443 | 3.5 | 200 | 225 |
4×95 + 1×50 | 1.1 | 2.2 | 42.4 | 2211 | 0.32 | 3.5 | 245 | 270 |
4×120 + 1×70 | 1.2 | 2.4 | 47.9 | 2677 | 0.253 | 3.5 | 285 | 310 |
4×150 + 1×70 | 1.4 | 2.5 | 51.9 | 3135 | 0.206 | 3.5 | 325 | 345 |
4×185 + 1×95 | 1.6 | 2.7 | 58 | 4038 | 0.164 | 3.5 | 375 | 390 |
4×240 + 1×120 | 1.7 | 2.9 | 65.1 | 4919 | 0.125 | 3.5 | 440 | 450 |
4×300 + 1×150 | 1.8 | 3.1 | 72 | 5957 | 0.1 | 3.5 | 505 | 515 |
Dum "Client-Oriented" philosophia usus est, summus qualitas administrationis methodi flagitat, productos innovans et etiam validos R&D vis laboris, semper libera merces qualitatis, solutiones superbas et incrementa pretia venditionis bonae qualitatis 0.6/1kv Low intentione Sub Copper/Aluminium Conductor XLPE Insulatus PVC Ferro Wire Armored Power Cable circumdedit, Societas nostra amice ex toto orbe benigne excipitur ad negotium visitandum, inquirendum et tractandum.
BonitasSina Cable et Electric CableProspicientes optimas rationes et solutiones, perfectissimum ministerium cum aequissimis pretiis principia nostra sunt.Nos quoque OEM et ODM ordines recipimus. Dedicati severae qualitati moderatio et curiosi servitii emptoris, praesto sumus semper ad de tuis postulatis disserere et plenam satisfactionem emptoris impendere.Amicos nobis sincere suscipimus ut ad negotia paciscenda veniamus et cooperationem incipiamus.