Aluminium Conductor Copper Conductor Electrical Power Cable

Description:

0.6/1kv Xlpe insulata Pvc vaginatus aluminium funem potentiae adhibentur ad distributionem potestatis in stationibus potentiae, institutionis industrialis et switchgears, necnon in locis mains.Tractationem in institutione certa ferre possunt.Ad certam institutionem sub terra.

 

 

Acceptatio: OEM/ODM, Trade, Tutus, Regionalis Agency

Payment: T/T, L/C, PayPal


Product Detail

Product Tags

Intentio nostra consumeret impleret oblato aureo auxilio, magno pretio et qualitate pro Factory supplevit 0.6/1kv Aluminium Conductor Copperorum Conductor Electrical Potestatis Cable, "Qualitas", "honestas" et "servitium" nostrum principium est.Nostra fidelitas et officia apud Tuum obsequium reverenter maneant.Loquere ad nos hodie Nam etiam ulterior notitia, nunc nobiscum attinge.
Inten- tio nostra esset perussores nostros offerre aureum subsidium, magnum pretium ac qualitatemChina Electric Cable and Electrical Cable, Explicatio nostrarum societatis non solum cautione qualitatis, rationabili pretio ac perfectae servitutis indiget, sed etiam fiduciae et auxilio nostrae emptoris nititur!In futurum, perseveremus cum peritissimis et qualitate praestantissimis, ut pretium auctori- tissimi suppeditet, Una cum clientibus nostris, et vincere-vincere consequi!Grata inquisitione et consule!

Applicationem

Adhibentur in domesticis, in cuniculo vel funiculo fossae, rudentes non armatae, quae vires mechanicas externas ferre non possunt.

Construction

AVAV

Characteres

Rated voltage 0.6/1kV
Conductor aluminium
Insulation XLPE
Vagina PVC
Core 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Color Nigrum vel nativus

Signa

GB/T 12706、IEC、BS、DIN et ICEA postulante

Morbi laoreet

2 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

2×4

0.7

1.8

11.4

150

7.41

3.5

34

45

2×6

0.7

1.8

12.4

171

4.61

3.5

43

57

2×10

0.7

1.8

14.9

238

3.08

3.5

60

77

2×16

0.7

1.8

17.1

294

1.91

3.5

83

105

2×25

0.9

1.8

20

394

1.2

3.5

105

125

2×35

0.9

1.8

22

484

0.868

3.5

125

155

2×50

1

1.8

23.4

497

0.641

3.5

160

185

2×70

1.1

1.8

24.5

640

0.443

3.5

200

225

2×95

1.1

1.9

28.6

827

0.32

3.5

245

270

2×120

1.2

2

29.7

1015

0.253

3.5

285

310

2×150

1.4

2.2

31.2

1268

0.206

3.5

325

345

3 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4

0.7

1.8

12

163

7.41

3.5

34

45

3×6

0.7

1.8

13

191

4.61

3.5

43

57

3×10

0.7

1.8

15.8

282

3.08

3.5

60

77

3×16

0.7

1.8

18.2

358

1.91

3.5

83

105

3×25

0.9

1.8

21.3

491

1.2

3.5

105

125

3×35

0.9

1.8

23.6

600

0.868

3.5

125

155

3×50

1

1.8

23.8

729

0.641

3.5

160

185

3×70

1.1

1.9

27.4

958

0.443

3.5

200

225

3×95

1.1

2

33.1

1242

0.32

3.5

245

270

3×120

1.2

2.1

34.7

1502

0.253

3.5

285

310

3×150

1.4

2.3

39.1

1875

0.206

3.5

325

345

3× 185

1.6

2.4

42.3

2264

0.164

3.5

375

390

3×240

1.7

2.6

47.8

2861

0.125

3.5

440

450

3×300

1.8

2.8

52.4

3501

0.1

3.5

505

515

3×400

2

3.1

62.9

4627

0.0078

3.5

570

575

4 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4

0.7

1.8

13

197

7.41

3.5

34

45

4×6

0.7

1.8

14.2

233

4.61

3.5

43

57

4×10

0.7

1.8

17.2

345

3.08

3.5

60

77

4×16

0.7

1.8

19.9

442

1.91

3.5

83

105

4×25

0.9

1.8

23.4

595

1.2

3.5

105

125

4×35

0.9

1.8

25.8

734

0.868

3.5

125

155

4×50

1

1.9

27.2

912

0.641

3.5

160

185

4×70

1.1

2

27.9

1207

0.443

3.5

200

225

4×95

1.1

2.1

33.8

1569

0.32

3.5

245

270

4×120

1.2

2.3

35.8

1923

0.253

3.5

285

310

4×150

1.4

2.4

40.2

2374

0.206

3.5

325

345

4× 185

1.6

2.6

43.6

2899

0.164

3.5

375

390

4×240

1.7

2.8

49.3

3670

0.125

3.5

440

450

4×300

1.8

3

54.1

4499

0.1

3.5

505

515

4×400

2

3.3

65.1

5947

0.0078

3.5

570

575

5 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

5×4

0.7

1.8

14

223

7.41

3.5

34

45

5×6

0.7

1.8

15.3

266

4.61

3.5

43

57

5×10

0.7

1.8

18.7

395

3.08

3.5

60

77

5×16

0.7

1.8

21.7

512

1.91

3.5

83

105

5×25

0.9

1.8

25.6

700

1.2

3.5

105

125

5×35

0.9

1.8

28.3

872

0.868

3.5

125

155

5×50

1

2

31.6

1155

0.641

3.5

160

185

5×70

1.1

2.1

37.2

1536

0.443

3.5

200

225

5×95

1.1

2.3

41

1971

0.32

3.5

245

270

5×120

1.2

2.4

46.2

2430

0.253

3.5

285

310

5×150

1.4

2.6

50.8

3036

0.206

3.5

325

345

5× 185

1.6

2.8

56.6

3716

0.164

3.5

375

390

5×240

1.7

3

62.8

4677

0.125

3.5

440

450

5×300

1.8

3.2

71.4

5758

0.1

3.5

505

515

3+1 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 1×2.5

0.7

1.8

12.7

189

7.41

3.5

34

45

3×6 + 1×4

0.7

1.8

13.9

224

4.61

3.5

43

57

3×10 + 1×6

0.7

1.8

16.4

311

3.08

3.5

60

77

3×16 + 1×10

0.7

1.8

19.2

418

1.91

3.5

83

105

3×25 + 1×16

0.9

1.8

22.5

557

1.2

3.5

105

125

3×35 + 1×16

0.9

1.8

25

667

0.868

3.5

125

155

3×50 + 1×25

1

1.8

25.5

833

0.641

3.5

160

185

3×70 + 1×35

1.1

1.9

28.9

1096

0.443

3.5

200

225

3×95 + 1×50

1.1

2.1

35.3

1448

0.32

3.5

245

270

3×120 + 1×70

1.2

2.2

37.1

1787

0.253

3.5

285

310

3×150 + 1×70

1.4

2.3

41.7

2143

0.206

3.5

325

345

3×185 + 1×95

1.6

2.5

45.3

2629

0.164

3.5

375

390

3×240 + 1×120

1.7

2.7

51.3

3314

0.125

3.5

440

450

3×300 + 1×150

1.8

2.9

56.3

4062

0.1

3.5

505

515

3×400 + 1×240

2

3.1

67.6

5295

0.0078

3.5

570

575

3+2 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 2×2.5

0.7

1.8

13.5

208

7.41

3.5

34

45

3×6 + 2×4

0.7

1.8

14.8

249

4.61

3.5

43

57

3×10 + 2×6

0.7

1.8

17.4

343

3.08

3.5

60

77

3×16 + 2×10

0.7

1.8

20.5

465

1.91

3.5

83

105

3×25 + 2×16

0.9

1.8

24

625

1.2

3.5

105

125

3×35 + 2×16

0.9

1.8

25.7

728

0.868

3.5

125

155

3×50 + 2×35

1

1.9

29

980

0.641

3.5

160

185

3×70 + 2×35

1.1

2

33.8

1284

0.443

3.5

200

225

3×95 + 2×50

1.1

2.2

37.4

1660

0.32

3.5

245

270

3×120 + 2×70

1.2

2.3

42.8

2089

0.253

3.5

285

310

3×150 + 2×70

1.4

2.4

45.2

2424

0.206

3.5

325

345

3×185 + 2×95

1.6

2.6

50.6

3010

0.164

3.5

375

390

3×240 + 2×120

1.7

2.8

56

3772

0.125

3.5

440

450

3×300 + 2×150

1.8

3

64.6

4673

0.1

3.5

505

515

4+1 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×6 + 1×4

0.7

1.8

15

259

4.61

3.5

43

57

4×10 + 1×6

0.7

1.8

17.7

364

3.08

3.5

60

77

4×16 + 1×10

0.7

1.8

20.3

490

1.91

3.5

83

105

4×25 + 1×16

0.9

1.8

24.2

665

1.2

3.5

105

125

4×35 + 1×16

0.9

1.8

26.4

803

0.868

3.5

125

155

4×50 + 1×25

1

1.9

32.6

1114

0.641

3.5

160

185

4×70 + 1×35

1.1

2.1

37.4

1806

0.443

3.5

200

225

4×95 + 1×50

1.1

2.2

42.4

2211

0.32

3.5

245

270

4×120 + 1×70

1.2

2.4

47.9

2677

0.253

3.5

285

310

4×150 + 1×70

1.4

2.5

51.9

3135

0.206

3.5

325

345

4×185 + 1×95

1.6

2.7

58

4038

0.164

3.5

375

390

4×240 + 1×120

1.7

2.9

65.1

4919

0.125

3.5

440

450

4×300 + 1×150

1.8

3.1

72

5957

0.1

3.5

505

515

Intentio nostra consumeret impleret oblato aureo auxilio, magno pretio et qualitate pro Factory supplevit 0.6/1kv Aluminium Conductor Copperorum Conductor Electrical Potestatis Cable, "Qualitas", "honestas" et "servitium" nostrum principium est.Nostra fidelitas et officia apud Tuum obsequium reverenter maneant.Loquere ad nos hodie Nam etiam ulterior notitia, nunc nobiscum attinge.
Factory suppleveruntChina Electric Cable and Electrical Cable, Explicatio nostrarum societatis non solum cautione qualitatis, rationabili pretio ac perfectae servitutis indiget, sed etiam fiduciae et auxilio nostrae emptoris nititur!In futurum, perseveremus cum peritissimis et qualitate praestantissimis, ut pretium auctori- tissimi suppeditet, Una cum clientibus nostris, et vincere-vincere consequi!Grata inquisitione et consule!


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis