Sina cheap price Low Voltage Multicore XLPE Insalted inermis Power Cable cum Ce certificatorium

Description:

Funes pro electricitate copiae in humili intentione institutionis systematis adhibentur, aptae sunt ad institutionem in tectis et foris, in ductus funiculi, sub terra, in potestate et commutatione stationum, distributiones industriae locales, plantae industriales, ubi periculum mechanicae non est. damno.

 

 

Acceptatio: OEM/ODM, Trade, Tutus, Regionalis Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

Nostrae solutiones late cognoscuntur et confidunt a consumers et occurrent cum assidue oeconomicis et socialibus exigentiis pro Sinis pretium Low Voltage Multicore XLPE Insaltum Insaltum Potestate Cable cum Ce Certificate, hanc occasionem accipere volumus ut relationes diuturnae incepti cognoscendi cum clientibus suis de toto orbe terrarum.
Solutiones nostrae late cognoscuntur et confidunt ab ussoribus et occurrent semper oeconomicis et socialibus elaborandisSina inermis cable et infima intentione virtutis cableTe suscipimus, ut societatem nostram et officinam invisas.Convenit etiam ad nostrum locum visitandum.Nostrae venditionesque turmae tibi optimam servitutem praebebunt.Si plus informationes habere debes, liberum contactus nos ab E-mail vel telephonio habere debes.Ex animo sumus spem bonam diuturnum negotium cum vobis necessitudinem constituere per hanc opportunitatem, pari ac mutua utilitate ex nunc in posterum fundatam.

Applicationem

Indomes funem trunking, foris pro statio potestatis, industria et switchgear tum pro retiacula urbana, si damnum mechanicum est inconveniens.

Construction

avava

Characteres

Ratum voltage: 0.6/1kV

1. Durante normali operatione funis, maxima conductor temperatus 70℃ pro insulatione PVC et 90" pro XLPE velit.
2.Maximum temperatura conductoris in ambitu brevi (maximam durationem non excedentem 5 secundis) : insulation PVC - 160℃ pro conductor sectione transversalis ≤300mm2, 140℃ conductor sectioni transversalis > 300mm2;Nulla in PVC Crosslinked 250℃.
3. Cum retinacula ponatur, temperatus ambiens non erit minor quam 0℃, et radius minimus flexor licitus talis est:
Uno cable core: inermis 20D, armatus 15D
Funis multi-core: 15D pro inermis, 12D pro armatis
Qua: D- diametro funis exterioris actualis.
4.Cable vi fractionis:
Aluminium core cable: 40×S (N)
Funis aeris: 70×S (N)
Nota: S est totalis area crucis-sectionalis conductoris

Signa

IEC 60502-1, GB/T 12706.1

Morbi laoreet

Unius Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0.0991

3.5

450

465

1×240

1.7

1.7

25

2510

0.093

3.5

535

540

1×300

1.8

1.8

27

3042

0.093

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0.078

3.5

835

780

1×630

2.4

2.2

40

6220

0.093

3.5

960

880

1×800

2.6

2.4

45

7870

0.0218

3.5

1110

970

1×1000

2.8

2.6

51

9804

0.0176

3.5

1230

1060

2 Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

3 Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3× 185

1.6

2.3

41

5654

0.0991

3.5

375

390

3×240

1.7

2.4

46

7243

0.093

3.5

440

450

3×300

1.8

2.6

51

9465

0.093

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

4 Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4× 185

1.6

2.3

42

7562

0.0991

3.5

375

390

4×240

1.7

2.5

47

9836

0.093

3.5

440

450

4×300

1.8

2.6

52

12550

0.093

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

5 Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5× 185

1.6

2.7

55

10215

0.0991

3.5

375

390

5×240

1.7

3

64

13130

0.093

3.5

440

450

5×300

1.8

3.2

70

16670

0.093

3.5

505

515

III + I Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1/4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3× 185+1×95

1.6

2.4

43

8501

0.0991

3.5

375

390

3× 240+1×120

1.7

2.5

48

11155

0.093

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0.093

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

3+2 Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0.0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0.093

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0.093

3.5

505

515

IV + I Core Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1/4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0.0991

3.5

375

390

4× 240+1×120

1.7

2.7

54

11567

0.093

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0.093

3.5

505

515

包装 与 运输Nostrae solutiones late cognoscuntur et confidunt a consumers et occurrent cum assidue oeconomicis et socialibus exigentiis pro Sinis pretium Low Voltage Multicore XLPE Insaltum Insaltum Potestate Cable cum Ce Certificate, hanc occasionem accipere volumus ut relationes diuturnae incepti cognoscendi cum clientibus suis de toto orbe terrarum.
China priceSina inermis cable et infima intentione virtutis cableTe suscipimus, ut societatem nostram et officinam invisas.Convenit etiam ad nostrum locum visitandum.Nostrae venditionesque turmae tibi optimam servitutem praebebunt.Si plus informationes habere debes, liberum contactus nos ab E-mail vel telephonio habere debes.Ex animo sumus spem bonam diuturnum negotium cum vobis necessitudinem constituere per hanc opportunitatem, pari ac mutua utilitate ex nunc in posterum fundatam.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis