0.6/1kv AL/XLPE/PVC Aluminium Power Cable

Description:

Conductor:aluminium

Insulatio:XLPE

Nulla Color:Red, Blue, Grey, Flavus/Green vel ad petitionem

Ratum Voltage:0.6/1KV

Jacket:PVC

Latin:IEC, UL, GB, JIS, GS, ASTM

Inscriptio:sales@zhongweicables.com

 

 

Acceptatio: OEM/ODM, Trade, Tutus, Regionalis Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

Applicationem

0.6/1kv Xlpe insulata Pvc vaginatus aluminium funem potentiae adhibentur ad distributionem potestatis in stationibus potentiae, institutionis industrialis et switchgears, necnon in locis mains.Tractationem in institutione certa ferre possunt.Ad certam institutionem sub terra.

Construction

AVAV

Characteres

Rated voltage 0.6/1kV
Conductor aluminium
Insulation XLPE
Vagina PVC
Core 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Color Nigrum vel nativus

Signa

GB/T 12706、IEC、BS、DIN et ICEA postulante

Morbi laoreet

2 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

2x4

0.7

1.8

11.4

150

7.41

3.5

34

45

2×6

0.7

1.8

12.4

171

4.61

3.5

43

57

2×10

0.7

1.8

14.9

238

3.08

3.5

60

77

2×16

0.7

1.8

17.1

294

1.91

3.5

83

105

2×25

0.9

1.8

20

394

1.2

3.5

105

125

2×35

0.9

1.8

22

484

0.868

3.5

125

155

2×50

1

1.8

23.4

497

0.641

3.5

160

185

2×70

1.1

1.8

24.5

640

0.443

3.5

200

225

2×95

1.1

1.9

28.6

827

0.32

3.5

245

270

2×120

1.2

2

29.7

1015

0.253

3.5

285

310

2×150

1.4

2.2

31.2

1268

0.206

3.5

325

345

3 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4

0.7

1.8

12

163

7.41

3.5

34

45

3×6

0.7

1.8

13

191

4.61

3.5

43

57

3×10

0.7

1.8

15.8

282

3.08

3.5

60

77

3×16

0.7

1.8

18.2

358

1.91

3.5

83

105

3×25

0.9

1.8

21.3

491

1.2

3.5

105

125

3×35

0.9

1.8

23.6

600

0.868

3.5

125

155

3×50

1

1.8

23.8

729

0.641

3.5

160

185

3×70

1.1

1.9

27.4

958

0.443

3.5

200

225

3×95

1.1

2

33.1

1242

0.32

3.5

245

270

3×120

1.2

2.1

34.7

1502

0.253

3.5

285

310

3×150

1.4

2.3

39.1

1875

0.206

3.5

325

345

3× 185

1.6

2.4

42.3

2264

0.164

3.5

375

390

3×240

1.7

2.6

47.8

2861

0.125

3.5

440

450

3×300

1.8

2.8

52.4

3501

0.1

3.5

505

515

3×400

2

3.1

62.9

4627

0.0078

3.5

570

575

4 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4

0.7

1.8

13

197

7.41

3.5

34

45

4×6

0.7

1.8

14.2

233

4.61

3.5

43

57

4×10

0.7

1.8

17.2

345

3.08

3.5

60

77

4×16

0.7

1.8

19.9

442

1.91

3.5

83

105

4×25

0.9

1.8

23.4

595

1.2

3.5

105

125

4×35

0.9

1.8

25.8

734

0.868

3.5

125

155

4×50

1

1.9

27.2

912

0.641

3.5

160

185

4×70

1.1

2

27.9

1207

0.443

3.5

200

225

4×95

1.1

2.1

33.8

1569

0.32

3.5

245

270

4×120

1.2

2.3

35.8

1923

0.253

3.5

285

310

4×150

1.4

2.4

40.2

2374

0.206

3.5

325

345

4× 185

1.6

2.6

43.6

2899

0.164

3.5

375

390

4×240

1.7

2.8

49.3

3670

0.125

3.5

440

450

4×300

1.8

3

54.1

4499

0.1

3.5

505

515

4×400

2

3.3

65.1

5947

0.0078

3.5

570

575

5 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

5×4

0.7

1.8

14

223

7.41

3.5

34

45

5×6

0.7

1.8

15.3

266

4.61

3.5

43

57

5×10

0.7

1.8

18.7

395

3.08

3.5

60

77

5×16

0.7

1.8

21.7

512

1.91

3.5

83

105

5×25

0.9

1.8

25.6

700

1.2

3.5

105

125

5×35

0.9

1.8

28.3

872

0.868

3.5

125

155

5×50

1

2

31.6

1155

0.641

3.5

160

185

5×70

1.1

2.1

37.2

1536

0.443

3.5

200

225

5×95

1.1

2.3

41

1971

0.32

3.5

245

270

5×120

1.2

2.4

46.2

2430

0.253

3.5

285

310

5×150

1.4

2.6

50.8

3036

0.206

3.5

325

345

5× 185

1.6

2.8

56.6

3716

0.164

3.5

375

390

5×240

1.7

3

62.8

4677

0.125

3.5

440

450

5×300

1.8

3.2

71.4

5758

0.1

3.5

505

515

3+1 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 1×2.5

0.7

1.8

12.7

189

7.41

3.5

34

45

3×6 + 1×4

0.7

1.8

13.9

224

4.61

3.5

43

57

3×10 + 1×6

0.7

1.8

16.4

311

3.08

3.5

60

77

3×16 + 1×10

0.7

1.8

19.2

418

1.91

3.5

83

105

3×25 + 1×16

0.9

1.8

22.5

557

1.2

3.5

105

125

3×35 + 1×16

0.9

1.8

25

667

0.868

3.5

125

155

3×50 + 1×25

1

1.8

25.5

833

0.641

3.5

160

185

3×70 + 1×35

1.1

1.9

28.9

1096

0.443

3.5

200

225

3×95 + 1×50

1.1

2.1

35.3

1448

0.32

3.5

245

270

3×120 + 1×70

1.2

2.2

37.1

1787

0.253

3.5

285

310

3×150 + 1×70

1.4

2.3

41.7

2143

0.206

3.5

325

345

3×185 + 1×95

1.6

2.5

45.3

2629

0.164

3.5

375

390

3×240 + 1×120

1.7

2.7

51.3

3314

0.125

3.5

440

450

3×300 + 1×150

1.8

2.9

56.3

4062

0.1

3.5

505

515

3×400 + 1×240

2

3.1

67.6

5295

0.0078

3.5

570

575

3+2 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 2×2.5

0.7

1.8

13.5

208

7.41

3.5

34

45

3×6 + 2×4

0.7

1.8

14.8

249

4.61

3.5

43

57

3×10 + 2×6

0.7

1.8

17.4

343

3.08

3.5

60

77

3×16 + 2×10

0.7

1.8

20.5

465

1.91

3.5

83

105

3×25 + 2×16

0.9

1.8

24

625

1.2

3.5

105

125

3×35 + 2×16

0.9

1.8

25.7

728

0.868

3.5

125

155

3×50 + 2×35

1

1.9

29

980

0.641

3.5

160

185

3×70 + 2×35

1.1

2

33.8

1284

0.443

3.5

200

225

3×95 + 2×50

1.1

2.2

37.4

1660

0.32

3.5

245

270

3×120 + 2×70

1.2

2.3

42.8

2089

0.253

3.5

285

310

3×150 + 2×70

1.4

2.4

45.2

2424

0.206

3.5

325

345

3×185 + 2×95

1.6

2.6

50.6

3010

0.164

3.5

375

390

3×240 + 2×120

1.7

2.8

56

3772

0.125

3.5

440

450

3×300 + 2×150

1.8

3

64.6

4673

0.1

3.5

505

515

4+1 Core Aluminium Power Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×6 + 1×4

0.7

1.8

15

259

4.61

3.5

43

57

4×10 + 1×6

0.7

1.8

17.7

364

3.08

3.5

60

77

4×16 + 1×10

0.7

1.8

20.3

490

1.91

3.5

83

105

4×25 + 1×16

0.9

1.8

24.2

665

1.2

3.5

105

125

4×35 + 1×16

0.9

1.8

26.4

803

0.868

3.5

125

155

4×50 + 1×25

1

1.9

32.6

1114

0.641

3.5

160

185

4×70 + 1×35

1.1

2.1

37.4

1806

0.443

3.5

200

225

4×95 + 1×50

1.1

2.2

42.4

2211

0.32

3.5

245

270

4×120 + 1×70

1.2

2.4

47.9

2677

0.253

3.5

285

310

4×150 + 1×70

1.4

2.5

51.9

3135

0.206

3.5

325

345

4×185 + 1×95

1.6

2.7

58

4038

0.164

3.5

375

390

4×240 + 1×120

1.7

2.9

65.1

4919

0.125

3.5

440

450

4×300 + 1×150

1.8

3.1

72

5957

0.1

3.5

505

515

Stipare & Shipping

FAQ

Q: Possumusne nostrum logo vel societatis nomen imprimi in vestra producta vel in sarcina?
A: Ordo OEM & ODM vehementer gratus est et nos in inceptis OEM plene feliciter experimur.Quid amplius, nostra R&D turma dabit tibi suggestiones professionales.
Q: Quid mercedem verbis?
A: 30% T/T depositum, 70% T/T staterae solutionis ante shipment.
Q: Quomodo vestra officinam facit de qualitate potestate?
A: Arcam qualitatem temperantiae systematis habemus, et periti professionales nostros aspectum ac testium functionum omnium rerum nostrarum ante amet.
Q: Quomodo possum exemplum probare qualitatem tuam?
A: Libera exempla praebere possumus pro experimento et reprimendo, onera onera sustinenda iustus postulo.

Contact us pro pluribus informationibus de fructibus nostris, turma nostra professio serviet tibi et nativus secundum exigentias tuas.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis