0.6/1kv AL/XLPE/PVC Aluminium Power Cable
Applicationem
0.6/1kv Xlpe insulata Pvc vaginatus aluminium funem potentiae adhibentur ad distributionem potestatis in stationibus potentiae, institutionis industrialis et switchgears, necnon in locis mains.Tractationem in institutione certa ferre possunt.Ad certam institutionem sub terra.
Construction
Characteres
Rated voltage | 0.6/1kV |
Conductor | aluminium |
Insulation | XLPE |
Vagina | PVC |
Core | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
Color | Nigrum vel nativus |
Signa
GB/T 12706、IEC、BS、DIN et ICEA postulante
Morbi laoreet
2 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
2x4 | 0.7 | 1.8 | 11.4 | 150 | 7.41 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.8 | 12.4 | 171 | 4.61 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.8 | 14.9 | 238 | 3.08 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.8 | 17.1 | 294 | 1.91 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.8 | 20 | 394 | 1.2 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.8 | 22 | 484 | 0.868 | 3.5 | 125 | 155 |
2×50 | 1 | 1.8 | 23.4 | 497 | 0.641 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 24.5 | 640 | 0.443 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.9 | 28.6 | 827 | 0.32 | 3.5 | 245 | 270 |
2×120 | 1.2 | 2 | 29.7 | 1015 | 0.253 | 3.5 | 285 | 310 |
2×150 | 1.4 | 2.2 | 31.2 | 1268 | 0.206 | 3.5 | 325 | 345 |
3 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 | 0.7 | 1.8 | 12 | 163 | 7.41 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.8 | 13 | 191 | 4.61 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.8 | 15.8 | 282 | 3.08 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.8 | 18.2 | 358 | 1.91 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.8 | 21.3 | 491 | 1.2 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.8 | 23.6 | 600 | 0.868 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 23.8 | 729 | 0.641 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.9 | 27.4 | 958 | 0.443 | 3.5 | 200 | 225 |
3×95 | 1.1 | 2 | 33.1 | 1242 | 0.32 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2.1 | 34.7 | 1502 | 0.253 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2.3 | 39.1 | 1875 | 0.206 | 3.5 | 325 | 345 |
3× 185 | 1.6 | 2.4 | 42.3 | 2264 | 0.164 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.6 | 47.8 | 2861 | 0.125 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.8 | 52.4 | 3501 | 0.1 | 3.5 | 505 | 515 |
3×400 | 2 | 3.1 | 62.9 | 4627 | 0.0078 | 3.5 | 570 | 575 |
4 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 | 0.7 | 1.8 | 13 | 197 | 7.41 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 14.2 | 233 | 4.61 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 17.2 | 345 | 3.08 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 19.9 | 442 | 1.91 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 23.4 | 595 | 1.2 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 25.8 | 734 | 0.868 | 3.5 | 125 | 155 |
4×50 | 1 | 1.9 | 27.2 | 912 | 0.641 | 3.5 | 160 | 185 |
4×70 | 1.1 | 2 | 27.9 | 1207 | 0.443 | 3.5 | 200 | 225 |
4×95 | 1.1 | 2.1 | 33.8 | 1569 | 0.32 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2.3 | 35.8 | 1923 | 0.253 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.4 | 40.2 | 2374 | 0.206 | 3.5 | 325 | 345 |
4× 185 | 1.6 | 2.6 | 43.6 | 2899 | 0.164 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.8 | 49.3 | 3670 | 0.125 | 3.5 | 440 | 450 |
4×300 | 1.8 | 3 | 54.1 | 4499 | 0.1 | 3.5 | 505 | 515 |
4×400 | 2 | 3.3 | 65.1 | 5947 | 0.0078 | 3.5 | 570 | 575 |
5 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
5×4 | 0.7 | 1.8 | 14 | 223 | 7.41 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1.8 | 15.3 | 266 | 4.61 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1.8 | 18.7 | 395 | 3.08 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1.8 | 21.7 | 512 | 1.91 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1.8 | 25.6 | 700 | 1.2 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1.8 | 28.3 | 872 | 0.868 | 3.5 | 125 | 155 |
5×50 | 1 | 2 | 31.6 | 1155 | 0.641 | 3.5 | 160 | 185 |
5×70 | 1.1 | 2.1 | 37.2 | 1536 | 0.443 | 3.5 | 200 | 225 |
5×95 | 1.1 | 2.3 | 41 | 1971 | 0.32 | 3.5 | 245 | 270 |
5×120 | 1.2 | 2.4 | 46.2 | 2430 | 0.253 | 3.5 | 285 | 310 |
5×150 | 1.4 | 2.6 | 50.8 | 3036 | 0.206 | 3.5 | 325 | 345 |
5× 185 | 1.6 | 2.8 | 56.6 | 3716 | 0.164 | 3.5 | 375 | 390 |
5×240 | 1.7 | 3 | 62.8 | 4677 | 0.125 | 3.5 | 440 | 450 |
5×300 | 1.8 | 3.2 | 71.4 | 5758 | 0.1 | 3.5 | 505 | 515 |
3+1 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 1×2.5 | 0.7 | 1.8 | 12.7 | 189 | 7.41 | 3.5 | 34 | 45 |
3×6 + 1×4 | 0.7 | 1.8 | 13.9 | 224 | 4.61 | 3.5 | 43 | 57 |
3×10 + 1×6 | 0.7 | 1.8 | 16.4 | 311 | 3.08 | 3.5 | 60 | 77 |
3×16 + 1×10 | 0.7 | 1.8 | 19.2 | 418 | 1.91 | 3.5 | 83 | 105 |
3×25 + 1×16 | 0.9 | 1.8 | 22.5 | 557 | 1.2 | 3.5 | 105 | 125 |
3×35 + 1×16 | 0.9 | 1.8 | 25 | 667 | 0.868 | 3.5 | 125 | 155 |
3×50 + 1×25 | 1 | 1.8 | 25.5 | 833 | 0.641 | 3.5 | 160 | 185 |
3×70 + 1×35 | 1.1 | 1.9 | 28.9 | 1096 | 0.443 | 3.5 | 200 | 225 |
3×95 + 1×50 | 1.1 | 2.1 | 35.3 | 1448 | 0.32 | 3.5 | 245 | 270 |
3×120 + 1×70 | 1.2 | 2.2 | 37.1 | 1787 | 0.253 | 3.5 | 285 | 310 |
3×150 + 1×70 | 1.4 | 2.3 | 41.7 | 2143 | 0.206 | 3.5 | 325 | 345 |
3×185 + 1×95 | 1.6 | 2.5 | 45.3 | 2629 | 0.164 | 3.5 | 375 | 390 |
3×240 + 1×120 | 1.7 | 2.7 | 51.3 | 3314 | 0.125 | 3.5 | 440 | 450 |
3×300 + 1×150 | 1.8 | 2.9 | 56.3 | 4062 | 0.1 | 3.5 | 505 | 515 |
3×400 + 1×240 | 2 | 3.1 | 67.6 | 5295 | 0.0078 | 3.5 | 570 | 575 |
3+2 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 2×2.5 | 0.7 | 1.8 | 13.5 | 208 | 7.41 | 3.5 | 34 | 45 |
3×6 + 2×4 | 0.7 | 1.8 | 14.8 | 249 | 4.61 | 3.5 | 43 | 57 |
3×10 + 2×6 | 0.7 | 1.8 | 17.4 | 343 | 3.08 | 3.5 | 60 | 77 |
3×16 + 2×10 | 0.7 | 1.8 | 20.5 | 465 | 1.91 | 3.5 | 83 | 105 |
3×25 + 2×16 | 0.9 | 1.8 | 24 | 625 | 1.2 | 3.5 | 105 | 125 |
3×35 + 2×16 | 0.9 | 1.8 | 25.7 | 728 | 0.868 | 3.5 | 125 | 155 |
3×50 + 2×35 | 1 | 1.9 | 29 | 980 | 0.641 | 3.5 | 160 | 185 |
3×70 + 2×35 | 1.1 | 2 | 33.8 | 1284 | 0.443 | 3.5 | 200 | 225 |
3×95 + 2×50 | 1.1 | 2.2 | 37.4 | 1660 | 0.32 | 3.5 | 245 | 270 |
3×120 + 2×70 | 1.2 | 2.3 | 42.8 | 2089 | 0.253 | 3.5 | 285 | 310 |
3×150 + 2×70 | 1.4 | 2.4 | 45.2 | 2424 | 0.206 | 3.5 | 325 | 345 |
3×185 + 2×95 | 1.6 | 2.6 | 50.6 | 3010 | 0.164 | 3.5 | 375 | 390 |
3×240 + 2×120 | 1.7 | 2.8 | 56 | 3772 | 0.125 | 3.5 | 440 | 450 |
3×300 + 2×150 | 1.8 | 3 | 64.6 | 4673 | 0.1 | 3.5 | 505 | 515 |
4+1 Core Aluminium Power Cable | ||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×6 + 1×4 | 0.7 | 1.8 | 15 | 259 | 4.61 | 3.5 | 43 | 57 |
4×10 + 1×6 | 0.7 | 1.8 | 17.7 | 364 | 3.08 | 3.5 | 60 | 77 |
4×16 + 1×10 | 0.7 | 1.8 | 20.3 | 490 | 1.91 | 3.5 | 83 | 105 |
4×25 + 1×16 | 0.9 | 1.8 | 24.2 | 665 | 1.2 | 3.5 | 105 | 125 |
4×35 + 1×16 | 0.9 | 1.8 | 26.4 | 803 | 0.868 | 3.5 | 125 | 155 |
4×50 + 1×25 | 1 | 1.9 | 32.6 | 1114 | 0.641 | 3.5 | 160 | 185 |
4×70 + 1×35 | 1.1 | 2.1 | 37.4 | 1806 | 0.443 | 3.5 | 200 | 225 |
4×95 + 1×50 | 1.1 | 2.2 | 42.4 | 2211 | 0.32 | 3.5 | 245 | 270 |
4×120 + 1×70 | 1.2 | 2.4 | 47.9 | 2677 | 0.253 | 3.5 | 285 | 310 |
4×150 + 1×70 | 1.4 | 2.5 | 51.9 | 3135 | 0.206 | 3.5 | 325 | 345 |
4×185 + 1×95 | 1.6 | 2.7 | 58 | 4038 | 0.164 | 3.5 | 375 | 390 |
4×240 + 1×120 | 1.7 | 2.9 | 65.1 | 4919 | 0.125 | 3.5 | 440 | 450 |
4×300 + 1×150 | 1.8 | 3.1 | 72 | 5957 | 0.1 | 3.5 | 505 | 515 |
FAQ
Q: Possumusne nostrum logo vel societatis nomen imprimi in vestra producta vel in sarcina?
A: Ordo OEM & ODM vehementer gratus est et nos in inceptis OEM plene feliciter experimur.Quid amplius, nostra R&D turma dabit tibi suggestiones professionales.
Q: Quid mercedem verbis?
A: 30% T/T depositum, 70% T/T staterae solutionis ante shipment.
Q: Quomodo vestra officinam facit de qualitate potestate?
A: Arcam qualitatem temperantiae systematis habemus, et periti professionales nostros aspectum ac testium functionum omnium rerum nostrarum ante amet.
Q: Quomodo possum exemplum probare qualitatem tuam?
A: Libera exempla praebere possumus pro experimento et reprimendo, onera onera sustinenda iustus postulo.