Rationabile pretium pro 600/1000V Copper/Aluminium Conductor/Steel Tape Cable armatae aeris potentiae

Description:

Funem praecipue adhibentur ad distributionem potentiae in stationibus potentiae, institutionis industrialis et anni transigendis, sicut et in locis mains.Ad hastilia, aqua et terra, maiorem positivum pressuram ferre possunt.

 

 

Acceptatio: OEM/ODM, Trade, Tutus, Regionalis Agency

Payment: T/T, L/C, PayPal

Stock Sample is Free & Available


Product Detail

Product Tags

Tenet administrationem sequimur "Qualitas eximia est, Provisor summum est, Nomen primum", et sincere creabit et communicabit cum omni clientela pro Rationabili pretio 600/1000V Copper/Aluminium Conductor / Steel Tape Armored Potentia Cable Cupri posse dissolvere problemata emptoris quam celerrime discendo et lucrum pro emptoribus nostris facere.Pro iis qui superiore provisore et excellentibus indigent, pis nos eligunt gratias!
Praecipuam administrationem sequimur "Qualitas eximia est, Provisor supremus, Nomen primum", et sincere creabit et communicabit successum cum omni clientela proChina 1kvISO9001 assecuti sumus quod solidum fundamentum ulteriori progressioni praebet.Perseverantes in "qualitate magna, prompta traditio, pretium competitive", cooperationem cum clientibus tam transmarinis quam domestice firmatam repperimus, ac novas et veteres clientium altas commenta comparavimus.Nostrum magnum decus postulatis tuis occurrit.Nos sincere exspectans operam tuam.

Applicationem

Xlpe insulata pvc taenia ferrata Cable ferro vaginata componitur ex puro conductore aeris, XLPE velit, armatura taenia ferro, et vagina PVC flammea retardat.Multicores funes industriales idonei sunt ad 0.6/1KV intentionis aestimationis, quae gravitati mechanicae sustinere possunt, quae adhiberi possunt ad stationes potentias, subway, cuniculos, aedificia alta ortum, magnas conatus industriales et fodiendi, agri oleum, fodinae carbones, aliaque alia. loca intensiva retinacula electrica distributa.

Construction

AVAVBA

Characteres

Ratum voltage: 0.6 / 1 kV

Maximum Conductor Temperature: sub normali (90℃), subitis (130℃) vel ambitu brevi non plus quam 5 condiciones (250℃).
Min.Ambient Temp.0℃, post institutionem et solum cum funem in certo situ
Min.Tendens Badius: 12 x cable OD pro multi core

Signa

IEC 60502-1, GB/T 12706.1

Applicationem

linearum transmissio et distributio cum 50 Hz AC aestimata intentione Uo/U 0,6/1KV et infra portabuntur;Apta ad sepeliendum impositionem, non idonea ad pipelines impositio.

Morbi laoreet

2 CoreFerro Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

2×4

0.7

1.2

2×0.2

1.8

15

433

4.61

3.5

34

45

2×6

0.7

1.2

2×0.2

1.8

16

500

3.08

3.5

43

57

2×10

0.7

1.2

2×0.2

1.8

19

673

1.83

3.5

60

77

2×16

0.7

1.4

2×0.2

1.8

21

857

1.15

3.5

83

105

2×25

0.9

1.4

2×0.2

1.8

24

1173

0.727

3.5

105

125

2×35

0.9

1.6

2×0.2

1.8

25

1449

0.524

3.5

125

155

2×50

1

1.6

2×0.2

1.8

26

1877

0.387

3.5

160

185

2×70

1.1

1.8

2×0.2

1.8

27

2454

0.268

3.5

200

225

2×95

1.1

1.8

2×0.2

1.9

30

2483

0.193

3.5

245

270

2×120

1.2

2

2×0.2

2

33

4213

0.153

3.5

285

310

2×150

1.4

2

2×0.5

2.2

38

5087

0.124

3.5

325

345

III Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×1.5

0.7

1

2×0.2

1.5

13

273

12.1

3.5

20

27

3×2.5

0.7

1

2×0.2

1.5

14

321

7.41

3.5

26

35

3×4

0.7

1.2

2×0.2

1.5

15

390

4.61

3.5

34

45

3×6

0.7

1.2

2×0.2

1.5

16

471

3.08

3.5

43

57

3×10

0.7

1.4

2×0.2

1.5

18

622

1.83

3.5

60

77

3×16

0.7

1.4

2×0.2

2

22

1005

1.15

3.5

83

105

3×25

0.9

1.6

2×0.2

2

25

1371

0.727

3.5

105

125

3×35

0.9

1.6

2×0.2

2

27

1724

0.524

3.5

125

155

3×50

1

1.8

2×0.2

2

30

2247

0.387

3.5

160

185

3×70

1.1

1.8

2×0.2

2.5

35

3023

0.268

3.5

200

225

3×95

1.1

2

2×0.5

2.5

39

3825

0.193

3.5

245

270

3×120

1.2

2

2×0.5

2.5

42

4642

0.153

3.5

285

310

3×150

1.4

2

2×0.5

3

48

5767

0.124

3.5

325

345

3× 185

1.6

2.2

2×0.5

3

51

6895

0.0991

3.5

375

390

3×240

1.7

2.2

2×0.5

3

56

8617

0.093

3.5

440

450

3×300

1.8

2.2

2×0.5

3

59

10928

0.093

3.5

505

515

3×400

2

2.2

2×0.5

3.2

61

13556

0.047

3.5

570

575

IV Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4

0.7

1

2×0.2

1.5

16

454

4.61

3.5

34

45

4×6

0.7

1

2×0.2

1.5

17

557

3.08

3.5

43

57

4×10

0.7

1

2×0.2

2

20

791

1.83

3.5

60

77

4×16

0.7

1

2×0.2

2

23

1210

1.15

3.5

83

105

4×25

0.9

1

2×0.2

2

27

1672

0.727

3.5

105

125

4×35

0.9

1

2×0.2

2

29

2127

0.524

3.5

125

155

4×50

1

1

2×0.2

2

33

2802

0.387

3.5

160

185

4×70

1.1

1.2

2×0.2

2.5

38

3785

0.268

3.5

200

225

4×95

1.1

1.2

2×0.5

2.5

42

4829

0.193

3.5

245

270

4×120

1.2

1.4

2×0.5

3

47

6033

0.153

3.5

285

310

4×150

1.4

1.4

2×0.5

3

52

7356

0.124

3.5

325

345

4× 185

1.6

1.6

2×0.5

3

56

8806

0.0991

3.5

375

390

4×240

1.7

1.6

2×0.5

3

62

11182

0.093

3.5

440

450

4×300

1.8

1.7

2×0.5

3.1

64

14176

0.093

3.5

505

515

4×400

2

1.7

2×0.5

3.5

69

17815

0.047

3.5

570

575

V Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

5×4

0.7

1

2×0.2

1.5

17.1

588

4.61

3.5

34

45

5×6

0.7

1

2×0.2

1.5

19.4

720

3.08

3.5

43

57

5×10

0.7

1

2×0.2

2

22.9

1014

1.83

3.5

60

77

5×16

0.7

1

2×0.2

2

25.8

1392

1.15

3.5

83

105

5×25

0.9

1

2×0.2

2

30.5

2002

0.727

3.5

105

125

5×35

0.9

1

2×0.2

2

33.7

2581

0.524

3.5

125

155

5×50

1

1

2×0.5

2

38.6

3722

0.387

3.5

160

185

5×70

1.1

1.2

2×0.5

2.5

43.4

4897

0.268

3.5

200

225

5×95

1.1

1.2

2×0.5

2.5

48.6

6338

0.193

3.5

245

270

5×120

1.2

1.4

2×0.5

3

54.4

7851

0.153

3.5

285

310

5×150

1.4

1.4

2×0.5

3

60.1

9661

0.124

3.5

325

345

5× 185

1.6

1.6

2×0.5

3

66.7

11770

0.0991

3.5

375

390

5×240

1.7

1.6

2×0.5

3

74.7

14900

0.093

3.5

440

450

5×300

1.8

1.7

2×0.5

3.1

83.2

18000

0.093

3.5

505

515

III + I Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 1×2.5

0.7

1

2×0.2

1.5

16

443

4.61

3.5

34

45

3×6 + 1×4

0.7

1

2×0.2

1.5

17

531

3.08

3.5

43

57

3×10 + 1×6

0.7

1

2×0.2

2

20

741

1.83

3.5

60

77

3×16 + 1×10

0.7

1

2×0.2

2

23

1135

1.15

3.5

83

105

3×25 + 1×16

0.9

1

2×0.2

2

26

1556

0.727

3.5

105

125

3×35 + 1×16

0.9

1

2×0.2

2

28

1896

0.524

3.5

125

155

3×50 + 1×25

1

1

2×0.2

2

31

2518

0.387

3.5

160

185

3×70 + 1×35

1.1

1.2

2×0.2

2.5

36

3293

0.268

3.5

200

225

3×95 + 1×50

1.1

1.2

2×0.5

2.5

40

4349

0.193

3.5

245

270

3×120 + 1×70

1.2

1.2

2×0.5

2.5

44

5365

0.153

3.5

285

310

3×150 + 1×70

1.4

1.4

2×0.5

3

49

6468

0.124

3.5

325

345

3×185 + 1×95

1.6

1.4

2×0.5

3

52

7854

0.0991

3.5

375

390

3×240 + 1×120

1.7

1.6

2×0.5

3.5

68

9814

0.093

3.5

440

450

3×300 + 1×150

1.8

1.7

2×0.5

3.5

71

12781

0.093

3.5

505

515

3×400 + 1×240

2

1.7

2×0.5

3.5

76

16359

0.047

3.5

570

575

3+2 Core Steel Tape Armored Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 2×2.5

0.7

1

2×0.2

1.5

17.5

855

4.61

3.5

34

45

3×6 + 2×4

0.7

1

2×0.2

1.5

18.9

1009

3.08

3.5

43

57

3×10 + 2×6

0.7

1

2×0.2

2

21.6

1461

1.83

3.5

60

77

3×16 + 2×10

0.7

1

2×0.2

2

24.6

1877

1.15

3.5

83

105

3×25 + 2×16

0.9

1

2×0.2

2

28.7

2583

0.727

3.5

105

125

3×35 + 2×16

0.9

1

2×0.2

2

30.7

3001

0.524

3.5

125

155

3×50 + 2×35

1

1

2×0.2

2

36.2

4392

0.387

3.5

160

185

3×70 + 2×35

1.1

1.2

2×0.2

2.5

40.3

5519

0.268

3.5

200

225

3×95 + 2×50

1.1

1.2

2×0.5

2.5

44.9

7543

0.193

3.5

245

270

3×120 + 2×70

1.2

1.2

2×0.5

2.5

50.3

9203

0.153

3.5

285

310

3×150 + 2×70

1.4

1.4

2×0.5

3

54

10485

0.124

3.5

325

345

3×185 + 2×95

1.6

1.4

2×0.5

3

60.2

13945

0.0991

3.5

375

390

3×240 + 2×120

1.7

1.6

2×0.5

3.5

67.2

15643

0.093

3.5

440

450

3×300 + 2×150

1.8

1.7

2×0.5

3.5

75.2

18204

0.093

3.5

505

515

IV + I Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4 + 1×2.5

0.7

1

2×0.2

1.5

18.4

565

4.61

3.5

34

45

4×6 + 1×4

0.7

1

2×0.2

1.5

19.8

692

3.08

3.5

43

57

4×10 + 1×6

0.7

1

2×0.2

2

22.8

953

1.83

3.5

60

77

4×16 + 1×10

0.7

1

2×0.2

2

25.8

1318

1.15

3.5

83

105

4×25 + 1×16

0.9

1

2×0.2

2

30.4

1877

0.727

3.5

105

125

4×35 + 1×16

0.9

1

2×0.2

2

34.1

2324

0.524

3.5

125

155

4×50 + 1×25

1

1

2×0.2

2

38.7

3415

0.387

3.5

160

185

4×70 + 1×35

1.1

1.2

2×0.5

2.5

44.2

4432

0.268

3.5

200

225

4×95 + 1×50

1.1

1.2

2×0.5

2.5

49.8

5747

0.193

3.5

245

270

4×120 + 1×70

1.2

1.2

2×0.5

2.5

55.4

7112

0.153

3.5

285

310

4×150 + 1×70

1.4

1.4

2×0.5

3

60.1

8556

0.124

3.5

325

345

4×185 + 1×95

1.6

1.4

2×0.5

3

66.9

10510

0.0991

3.5

375

390

4×240 + 1×120

1.7

1.6

2×0.5

3.5

74.8

13232

0.093

3.5

440

450

4×300 + 1×150

1.8

1.7

2×0.5

3.5

78.4

16452

0.093

3.5

505

515

包装 与 运输Tenet administrationem sequimur "Qualitas eximia est, Provisor summum est, Nomen primum", et sincere creabit et communicabit cum omni clientela pro Rationabili pretio 600/1000V Copper/Aluminium Conductor / Steel Tape Armored Potentia Cable Cupri posse dissolvere problemata emptoris quam celerrime discendo et lucrum pro emptoribus nostris facere.Pro iis qui superiore provisore et excellentibus indigent, pis nos eligunt gratias!
Rationabile pretium proChina 1kvISO9001 assecuti sumus quod solidum fundamentum ulteriori progressioni praebet.Perseverantes in "qualitate magna, prompta traditio, pretium competitive", cooperationem cum clientibus tam transmarinis quam domestice firmatam repperimus, ac novas et veteres clientium altas commenta comparavimus.Nostrum magnum decus postulatis tuis occurrit.Nos sincere exspectans operam tuam.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis