OEM/ODM Supplier 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminium/Core Steel Wire PVC/XLPE Subterranea Power Armored Best Sell Cable
Manemus cum praecipuo principio "qualitatis initio, officia prima, stabilis emendatio et innovatio ad clientes implendos" pro administratione tua ac "nulla defectus, nulla querela" pro qualitate obiectiva.Ad nostram societatem perficiendam, bona damus dum bona GENERALIS rationabili venditionis pretio utendo pro OEM/ODM Supplier 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminium/Copper Core Steel Wire PVC/XLPE Underground Power Armored Best Sell Cable, Pecuniam tuam nobis in negotiis tuis inceptis in tuto servandis.Spero nos in Sinis fidelem fore elit.Quaerendo cooperationem tuam .
Manemus cum praecipuo principio "qualitatis initio, officia prima, stabilis emendatio et innovatio ad clientes implendos" pro administratione tua ac "nulla defectus, nulla querela" pro qualitate obiectiva.Ad nostram societatem perficiendam, bona damus dum bona GENERALIS utendo in pretio rationabili venditionisChina Cables and Power CablesIn posterum promittimus servare qualitatem excellentiam et uberiorem impensiorem effectivam, quanto efficacius post venditiones servitii nostris omnibus clientibus ubique terrarum ad communem progressum et altiorem utilitatem.
Applicationem
Xlpe insulata pvc taenia ferrata Cable ferro vaginata componitur ex puro conductore aeris, XLPE velit, armatura taenia ferro, et vagina PVC flammea retardat.Multicores funes industriales idonei sunt ad 0.6/1KV intentionis aestimationis, quae gravitati mechanicae sustinere possunt, quae adhiberi possunt ad stationes potentias, subway, cuniculos, aedificia alta ortum, magnas conatus industriales et fodiendi, agri oleum, fodinae carbones, aliaque alia. loca intensiva retinacula electrica distributa.
Construction
Characteres
Ratum voltage: 0.6 / 1 kV
Maximum Conductor Temperature: sub normali (90℃), subitis (130℃) vel ambitu brevi non plus quam 5 condiciones (250℃).
Min.Ambient Temp.0℃, post institutionem et solum cum funem in certo situ
Min.Tendens Badius: 12 x cable OD pro multi core
Signa
IEC 60502-1, GB/T 12706.1
Applicationem
linearum transmissio et distributio cum 50 Hz AC aestimata intentione Uo/U 0,6/1KV et infra portabuntur;Apta ad sepeliendum impositionem, non idonea ad pipelines impositio.
Morbi laoreet
2 CoreFerro Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
2×4 | 0.7 | 1.2 | 2×0.2 | 1.8 | 15 | 433 | 4.61 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.2 | 2×0.2 | 1.8 | 16 | 500 | 3.08 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.2 | 2×0.2 | 1.8 | 19 | 673 | 1.83 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.4 | 2×0.2 | 1.8 | 21 | 857 | 1.15 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.4 | 2×0.2 | 1.8 | 24 | 1173 | 0.727 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.6 | 2×0.2 | 1.8 | 25 | 1449 | 0.524 | 3.5 | 125 | 155 |
2×50 | 1 | 1.6 | 2×0.2 | 1.8 | 26 | 1877 | 0.387 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 2×0.2 | 1.8 | 27 | 2454 | 0.268 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.8 | 2×0.2 | 1.9 | 30 | 2483 | 0.193 | 3.5 | 245 | 270 |
2×120 | 1.2 | 2 | 2×0.2 | 2 | 33 | 4213 | 0.153 | 3.5 | 285 | 310 |
2×150 | 1.4 | 2 | 2×0.5 | 2.2 | 38 | 5087 | 0.124 | 3.5 | 325 | 345 |
III Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×1.5 | 0.7 | 1 | 2×0.2 | 1.5 | 13 | 273 | 12.1 | 3.5 | 20 | 27 |
3×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 14 | 321 | 7.41 | 3.5 | 26 | 35 |
3×4 | 0.7 | 1.2 | 2×0.2 | 1.5 | 15 | 390 | 4.61 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.2 | 2×0.2 | 1.5 | 16 | 471 | 3.08 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.4 | 2×0.2 | 1.5 | 18 | 622 | 1.83 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.4 | 2×0.2 | 2 | 22 | 1005 | 1.15 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.6 | 2×0.2 | 2 | 25 | 1371 | 0.727 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.6 | 2×0.2 | 2 | 27 | 1724 | 0.524 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 2×0.2 | 2 | 30 | 2247 | 0.387 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.8 | 2×0.2 | 2.5 | 35 | 3023 | 0.268 | 3.5 | 200 | 225 |
3×95 | 1.1 | 2 | 2×0.5 | 2.5 | 39 | 3825 | 0.193 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2 | 2×0.5 | 2.5 | 42 | 4642 | 0.153 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2 | 2×0.5 | 3 | 48 | 5767 | 0.124 | 3.5 | 325 | 345 |
3× 185 | 1.6 | 2.2 | 2×0.5 | 3 | 51 | 6895 | 0.0991 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.2 | 2×0.5 | 3 | 56 | 8617 | 0.093 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.2 | 2×0.5 | 3 | 59 | 10928 | 0.093 | 3.5 | 505 | 515 |
3×400 | 2 | 2.2 | 2×0.5 | 3.2 | 61 | 13556 | 0.047 | 3.5 | 570 | 575 |
IV Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 | 0.7 | 1 | 2×0.2 | 1.5 | 16 | 454 | 4.61 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1 | 2×0.2 | 1.5 | 17 | 557 | 3.08 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1 | 2×0.2 | 2 | 20 | 791 | 1.83 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1 | 2×0.2 | 2 | 23 | 1210 | 1.15 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1 | 2×0.2 | 2 | 27 | 1672 | 0.727 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1 | 2×0.2 | 2 | 29 | 2127 | 0.524 | 3.5 | 125 | 155 |
4×50 | 1 | 1 | 2×0.2 | 2 | 33 | 2802 | 0.387 | 3.5 | 160 | 185 |
4×70 | 1.1 | 1.2 | 2×0.2 | 2.5 | 38 | 3785 | 0.268 | 3.5 | 200 | 225 |
4×95 | 1.1 | 1.2 | 2×0.5 | 2.5 | 42 | 4829 | 0.193 | 3.5 | 245 | 270 |
4×120 | 1.2 | 1.4 | 2×0.5 | 3 | 47 | 6033 | 0.153 | 3.5 | 285 | 310 |
4×150 | 1.4 | 1.4 | 2×0.5 | 3 | 52 | 7356 | 0.124 | 3.5 | 325 | 345 |
4× 185 | 1.6 | 1.6 | 2×0.5 | 3 | 56 | 8806 | 0.0991 | 3.5 | 375 | 390 |
4×240 | 1.7 | 1.6 | 2×0.5 | 3 | 62 | 11182 | 0.093 | 3.5 | 440 | 450 |
4×300 | 1.8 | 1.7 | 2×0.5 | 3.1 | 64 | 14176 | 0.093 | 3.5 | 505 | 515 |
4×400 | 2 | 1.7 | 2×0.5 | 3.5 | 69 | 17815 | 0.047 | 3.5 | 570 | 575 |
V Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
5×4 | 0.7 | 1 | 2×0.2 | 1.5 | 17.1 | 588 | 4.61 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1 | 2×0.2 | 1.5 | 19.4 | 720 | 3.08 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1 | 2×0.2 | 2 | 22.9 | 1014 | 1.83 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1 | 2×0.2 | 2 | 25.8 | 1392 | 1.15 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1 | 2×0.2 | 2 | 30.5 | 2002 | 0.727 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1 | 2×0.2 | 2 | 33.7 | 2581 | 0.524 | 3.5 | 125 | 155 |
5×50 | 1 | 1 | 2×0.5 | 2 | 38.6 | 3722 | 0.387 | 3.5 | 160 | 185 |
5×70 | 1.1 | 1.2 | 2×0.5 | 2.5 | 43.4 | 4897 | 0.268 | 3.5 | 200 | 225 |
5×95 | 1.1 | 1.2 | 2×0.5 | 2.5 | 48.6 | 6338 | 0.193 | 3.5 | 245 | 270 |
5×120 | 1.2 | 1.4 | 2×0.5 | 3 | 54.4 | 7851 | 0.153 | 3.5 | 285 | 310 |
5×150 | 1.4 | 1.4 | 2×0.5 | 3 | 60.1 | 9661 | 0.124 | 3.5 | 325 | 345 |
5× 185 | 1.6 | 1.6 | 2×0.5 | 3 | 66.7 | 11770 | 0.0991 | 3.5 | 375 | 390 |
5×240 | 1.7 | 1.6 | 2×0.5 | 3 | 74.7 | 14900 | 0.093 | 3.5 | 440 | 450 |
5×300 | 1.8 | 1.7 | 2×0.5 | 3.1 | 83.2 | 18000 | 0.093 | 3.5 | 505 | 515 |
III + I Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 1×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 16 | 443 | 4.61 | 3.5 | 34 | 45 |
3×6 + 1×4 | 0.7 | 1 | 2×0.2 | 1.5 | 17 | 531 | 3.08 | 3.5 | 43 | 57 |
3×10 + 1×6 | 0.7 | 1 | 2×0.2 | 2 | 20 | 741 | 1.83 | 3.5 | 60 | 77 |
3×16 + 1×10 | 0.7 | 1 | 2×0.2 | 2 | 23 | 1135 | 1.15 | 3.5 | 83 | 105 |
3×25 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 26 | 1556 | 0.727 | 3.5 | 105 | 125 |
3×35 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 28 | 1896 | 0.524 | 3.5 | 125 | 155 |
3×50 + 1×25 | 1 | 1 | 2×0.2 | 2 | 31 | 2518 | 0.387 | 3.5 | 160 | 185 |
3×70 + 1×35 | 1.1 | 1.2 | 2×0.2 | 2.5 | 36 | 3293 | 0.268 | 3.5 | 200 | 225 |
3×95 + 1×50 | 1.1 | 1.2 | 2×0.5 | 2.5 | 40 | 4349 | 0.193 | 3.5 | 245 | 270 |
3×120 + 1×70 | 1.2 | 1.2 | 2×0.5 | 2.5 | 44 | 5365 | 0.153 | 3.5 | 285 | 310 |
3×150 + 1×70 | 1.4 | 1.4 | 2×0.5 | 3 | 49 | 6468 | 0.124 | 3.5 | 325 | 345 |
3×185 + 1×95 | 1.6 | 1.4 | 2×0.5 | 3 | 52 | 7854 | 0.0991 | 3.5 | 375 | 390 |
3×240 + 1×120 | 1.7 | 1.6 | 2×0.5 | 3.5 | 68 | 9814 | 0.093 | 3.5 | 440 | 450 |
3×300 + 1×150 | 1.8 | 1.7 | 2×0.5 | 3.5 | 71 | 12781 | 0.093 | 3.5 | 505 | 515 |
3×400 + 1×240 | 2 | 1.7 | 2×0.5 | 3.5 | 76 | 16359 | 0.047 | 3.5 | 570 | 575 |
3+2 Core Steel Tape Armored Cable | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 2×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 17.5 | 855 | 4.61 | 3.5 | 34 | 45 |
3×6 + 2×4 | 0.7 | 1 | 2×0.2 | 1.5 | 18.9 | 1009 | 3.08 | 3.5 | 43 | 57 |
3×10 + 2×6 | 0.7 | 1 | 2×0.2 | 2 | 21.6 | 1461 | 1.83 | 3.5 | 60 | 77 |
3×16 + 2×10 | 0.7 | 1 | 2×0.2 | 2 | 24.6 | 1877 | 1.15 | 3.5 | 83 | 105 |
3×25 + 2×16 | 0.9 | 1 | 2×0.2 | 2 | 28.7 | 2583 | 0.727 | 3.5 | 105 | 125 |
3×35 + 2×16 | 0.9 | 1 | 2×0.2 | 2 | 30.7 | 3001 | 0.524 | 3.5 | 125 | 155 |
3×50 + 2×35 | 1 | 1 | 2×0.2 | 2 | 36.2 | 4392 | 0.387 | 3.5 | 160 | 185 |
3×70 + 2×35 | 1.1 | 1.2 | 2×0.2 | 2.5 | 40.3 | 5519 | 0.268 | 3.5 | 200 | 225 |
3×95 + 2×50 | 1.1 | 1.2 | 2×0.5 | 2.5 | 44.9 | 7543 | 0.193 | 3.5 | 245 | 270 |
3×120 + 2×70 | 1.2 | 1.2 | 2×0.5 | 2.5 | 50.3 | 9203 | 0.153 | 3.5 | 285 | 310 |
3×150 + 2×70 | 1.4 | 1.4 | 2×0.5 | 3 | 54 | 10485 | 0.124 | 3.5 | 325 | 345 |
3×185 + 2×95 | 1.6 | 1.4 | 2×0.5 | 3 | 60.2 | 13945 | 0.0991 | 3.5 | 375 | 390 |
3×240 + 2×120 | 1.7 | 1.6 | 2×0.5 | 3.5 | 67.2 | 15643 | 0.093 | 3.5 | 440 | 450 |
3×300 + 2×150 | 1.8 | 1.7 | 2×0.5 | 3.5 | 75.2 | 18204 | 0.093 | 3.5 | 505 | 515 |
IV + I Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 + 1×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 18.4 | 565 | 4.61 | 3.5 | 34 | 45 |
4×6 + 1×4 | 0.7 | 1 | 2×0.2 | 1.5 | 19.8 | 692 | 3.08 | 3.5 | 43 | 57 |
4×10 + 1×6 | 0.7 | 1 | 2×0.2 | 2 | 22.8 | 953 | 1.83 | 3.5 | 60 | 77 |
4×16 + 1×10 | 0.7 | 1 | 2×0.2 | 2 | 25.8 | 1318 | 1.15 | 3.5 | 83 | 105 |
4×25 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 30.4 | 1877 | 0.727 | 3.5 | 105 | 125 |
4×35 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 34.1 | 2324 | 0.524 | 3.5 | 125 | 155 |
4×50 + 1×25 | 1 | 1 | 2×0.2 | 2 | 38.7 | 3415 | 0.387 | 3.5 | 160 | 185 |
4×70 + 1×35 | 1.1 | 1.2 | 2×0.5 | 2.5 | 44.2 | 4432 | 0.268 | 3.5 | 200 | 225 |
4×95 + 1×50 | 1.1 | 1.2 | 2×0.5 | 2.5 | 49.8 | 5747 | 0.193 | 3.5 | 245 | 270 |
4×120 + 1×70 | 1.2 | 1.2 | 2×0.5 | 2.5 | 55.4 | 7112 | 0.153 | 3.5 | 285 | 310 |
4×150 + 1×70 | 1.4 | 1.4 | 2×0.5 | 3 | 60.1 | 8556 | 0.124 | 3.5 | 325 | 345 |
4×185 + 1×95 | 1.6 | 1.4 | 2×0.5 | 3 | 66.9 | 10510 | 0.0991 | 3.5 | 375 | 390 |
4×240 + 1×120 | 1.7 | 1.6 | 2×0.5 | 3.5 | 74.8 | 13232 | 0.093 | 3.5 | 440 | 450 |
4×300 + 1×150 | 1.8 | 1.7 | 2×0.5 | 3.5 | 78.4 | 16452 | 0.093 | 3.5 | 505 | 515 |
Manemus cum praecipuo principio "qualitatis initio, officia prima, stabilis emendatio et innovatio ad clientes implendos" pro administratione tua ac "nulla defectus, nulla querela" pro qualitate obiectiva.Ad nostram societatem perficiendam, bona damus dum bona GENERALIS rationabili venditionis pretio utendo pro OEM/ODM Supplier 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminium/Copper Core Steel Wire PVC/XLPE Underground Power Armored Best Sell Cable, Pecuniam tuam nobis in negotiis tuis inceptis in tuto servandis.Spero nos in Sinis fidelem fore elit.Quaerendo cooperationem tuam .
OEM/ODM SupplierChina Cables and Power CablesIn posterum promittimus servare qualitatem excellentiam et uberiorem impensiorem effectivam, quanto efficacius post venditiones servitii nostris omnibus clientibus ubique terrarum ad communem progressum et altiorem utilitatem.