Core 2 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminium/Core Steel Wire PVC/XLPE
Promotionem extollimus et novos fructus in forum singulis annis inducimus ad Lupum Factory 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminium/Coppe Core Steel Wire PVC/XLPE Subterranea Power Armored Cable, Quo modo inceptum tuum bonum inceptum cum nostra corporatione incipiemus?Parati sumus, idoneos et impleti sumus superbia.Incipiamus novam ordinationem nostram cum fluctu novo.
Commonentes promotionem ac novos fructus in forum quotannis inducuntSinis filum et filum Cuprum, Ad bona creandi plura creandi, ubertas qualitates ac solutiones ac renovationes non solum bona nostra, sed nosmetipsos renovamus ut nos ante mundum et novissimum sed maxime vitalem servemus: ut omnes clientes contenti omnibus vobis offeramus. et convalescere simul.Verus esse victor, hic incipit!
Applicationem
Xlpe insulata pvc taenia ferrata Cable ferro vaginata componitur ex puro conductore aeris, XLPE velit, armatura taenia ferro, et vagina PVC flammea retardat.Multicores funes industriales idonei sunt ad 0.6/1KV intentionis aestimationis, quae gravitati mechanicae sustinere possunt, quae adhiberi possunt ad stationes potentias, subway, cuniculos, aedificia alta ortum, magnas conatus industriales et fodiendi, agri oleum, fodinae carbones, aliaque alia. loca intensiva retinacula electrica distributa.
Construction
Characteres
Ratum voltage: 0.6 / 1 kV
Maximum Conductor Temperature: sub normali (90℃), subitis (130℃) vel ambitu brevi non plus quam 5 condiciones (250℃).
Min.Ambient Temp.0℃, post institutionem et solum cum funem in certo situ
Min.Tendens Badius: 12 x cable OD pro multi core
Signa
IEC 60502-1, GB/T 12706.1
Applicationem
linearum transmissio et distributio cum 50 Hz AC aestimata intentione Uo/U 0,6/1KV et infra portabuntur;Apta ad sepeliendum impositionem, non idonea ad pipelines impositio.
Morbi laoreet
2 CoreFerro Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
2×4 | 0.7 | 1.2 | 2×0.2 | 1.8 | 15 | 433 | 4.61 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.2 | 2×0.2 | 1.8 | 16 | 500 | 3.08 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.2 | 2×0.2 | 1.8 | 19 | 673 | 1.83 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.4 | 2×0.2 | 1.8 | 21 | 857 | 1.15 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.4 | 2×0.2 | 1.8 | 24 | 1173 | 0.727 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.6 | 2×0.2 | 1.8 | 25 | 1449 | 0.524 | 3.5 | 125 | 155 |
2×50 | 1 | 1.6 | 2×0.2 | 1.8 | 26 | 1877 | 0.387 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 2×0.2 | 1.8 | 27 | 2454 | 0.268 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.8 | 2×0.2 | 1.9 | 30 | 2483 | 0.193 | 3.5 | 245 | 270 |
2×120 | 1.2 | 2 | 2×0.2 | 2 | 33 | 4213 | 0.153 | 3.5 | 285 | 310 |
2×150 | 1.4 | 2 | 2×0.5 | 2.2 | 38 | 5087 | 0.124 | 3.5 | 325 | 345 |
III Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×1.5 | 0.7 | 1 | 2×0.2 | 1.5 | 13 | 273 | 12.1 | 3.5 | 20 | 27 |
3×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 14 | 321 | 7.41 | 3.5 | 26 | 35 |
3×4 | 0.7 | 1.2 | 2×0.2 | 1.5 | 15 | 390 | 4.61 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.2 | 2×0.2 | 1.5 | 16 | 471 | 3.08 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.4 | 2×0.2 | 1.5 | 18 | 622 | 1.83 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.4 | 2×0.2 | 2 | 22 | 1005 | 1.15 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.6 | 2×0.2 | 2 | 25 | 1371 | 0.727 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.6 | 2×0.2 | 2 | 27 | 1724 | 0.524 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 2×0.2 | 2 | 30 | 2247 | 0.387 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.8 | 2×0.2 | 2.5 | 35 | 3023 | 0.268 | 3.5 | 200 | 225 |
3×95 | 1.1 | 2 | 2×0.5 | 2.5 | 39 | 3825 | 0.193 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2 | 2×0.5 | 2.5 | 42 | 4642 | 0.153 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2 | 2×0.5 | 3 | 48 | 5767 | 0.124 | 3.5 | 325 | 345 |
3× 185 | 1.6 | 2.2 | 2×0.5 | 3 | 51 | 6895 | 0.0991 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.2 | 2×0.5 | 3 | 56 | 8617 | 0.093 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.2 | 2×0.5 | 3 | 59 | 10928 | 0.093 | 3.5 | 505 | 515 |
3×400 | 2 | 2.2 | 2×0.5 | 3.2 | 61 | 13556 | 0.047 | 3.5 | 570 | 575 |
IV Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 | 0.7 | 1 | 2×0.2 | 1.5 | 16 | 454 | 4.61 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1 | 2×0.2 | 1.5 | 17 | 557 | 3.08 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1 | 2×0.2 | 2 | 20 | 791 | 1.83 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1 | 2×0.2 | 2 | 23 | 1210 | 1.15 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1 | 2×0.2 | 2 | 27 | 1672 | 0.727 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1 | 2×0.2 | 2 | 29 | 2127 | 0.524 | 3.5 | 125 | 155 |
4×50 | 1 | 1 | 2×0.2 | 2 | 33 | 2802 | 0.387 | 3.5 | 160 | 185 |
4×70 | 1.1 | 1.2 | 2×0.2 | 2.5 | 38 | 3785 | 0.268 | 3.5 | 200 | 225 |
4×95 | 1.1 | 1.2 | 2×0.5 | 2.5 | 42 | 4829 | 0.193 | 3.5 | 245 | 270 |
4×120 | 1.2 | 1.4 | 2×0.5 | 3 | 47 | 6033 | 0.153 | 3.5 | 285 | 310 |
4×150 | 1.4 | 1.4 | 2×0.5 | 3 | 52 | 7356 | 0.124 | 3.5 | 325 | 345 |
4× 185 | 1.6 | 1.6 | 2×0.5 | 3 | 56 | 8806 | 0.0991 | 3.5 | 375 | 390 |
4×240 | 1.7 | 1.6 | 2×0.5 | 3 | 62 | 11182 | 0.093 | 3.5 | 440 | 450 |
4×300 | 1.8 | 1.7 | 2×0.5 | 3.1 | 64 | 14176 | 0.093 | 3.5 | 505 | 515 |
4×400 | 2 | 1.7 | 2×0.5 | 3.5 | 69 | 17815 | 0.047 | 3.5 | 570 | 575 |
V Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
5×4 | 0.7 | 1 | 2×0.2 | 1.5 | 17.1 | 588 | 4.61 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1 | 2×0.2 | 1.5 | 19.4 | 720 | 3.08 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1 | 2×0.2 | 2 | 22.9 | 1014 | 1.83 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1 | 2×0.2 | 2 | 25.8 | 1392 | 1.15 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1 | 2×0.2 | 2 | 30.5 | 2002 | 0.727 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1 | 2×0.2 | 2 | 33.7 | 2581 | 0.524 | 3.5 | 125 | 155 |
5×50 | 1 | 1 | 2×0.5 | 2 | 38.6 | 3722 | 0.387 | 3.5 | 160 | 185 |
5×70 | 1.1 | 1.2 | 2×0.5 | 2.5 | 43.4 | 4897 | 0.268 | 3.5 | 200 | 225 |
5×95 | 1.1 | 1.2 | 2×0.5 | 2.5 | 48.6 | 6338 | 0.193 | 3.5 | 245 | 270 |
5×120 | 1.2 | 1.4 | 2×0.5 | 3 | 54.4 | 7851 | 0.153 | 3.5 | 285 | 310 |
5×150 | 1.4 | 1.4 | 2×0.5 | 3 | 60.1 | 9661 | 0.124 | 3.5 | 325 | 345 |
5× 185 | 1.6 | 1.6 | 2×0.5 | 3 | 66.7 | 11770 | 0.0991 | 3.5 | 375 | 390 |
5×240 | 1.7 | 1.6 | 2×0.5 | 3 | 74.7 | 14900 | 0.093 | 3.5 | 440 | 450 |
5×300 | 1.8 | 1.7 | 2×0.5 | 3.1 | 83.2 | 18000 | 0.093 | 3.5 | 505 | 515 |
III + I Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 1×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 16 | 443 | 4.61 | 3.5 | 34 | 45 |
3×6 + 1×4 | 0.7 | 1 | 2×0.2 | 1.5 | 17 | 531 | 3.08 | 3.5 | 43 | 57 |
3×10 + 1×6 | 0.7 | 1 | 2×0.2 | 2 | 20 | 741 | 1.83 | 3.5 | 60 | 77 |
3×16 + 1×10 | 0.7 | 1 | 2×0.2 | 2 | 23 | 1135 | 1.15 | 3.5 | 83 | 105 |
3×25 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 26 | 1556 | 0.727 | 3.5 | 105 | 125 |
3×35 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 28 | 1896 | 0.524 | 3.5 | 125 | 155 |
3×50 + 1×25 | 1 | 1 | 2×0.2 | 2 | 31 | 2518 | 0.387 | 3.5 | 160 | 185 |
3×70 + 1×35 | 1.1 | 1.2 | 2×0.2 | 2.5 | 36 | 3293 | 0.268 | 3.5 | 200 | 225 |
3×95 + 1×50 | 1.1 | 1.2 | 2×0.5 | 2.5 | 40 | 4349 | 0.193 | 3.5 | 245 | 270 |
3×120 + 1×70 | 1.2 | 1.2 | 2×0.5 | 2.5 | 44 | 5365 | 0.153 | 3.5 | 285 | 310 |
3×150 + 1×70 | 1.4 | 1.4 | 2×0.5 | 3 | 49 | 6468 | 0.124 | 3.5 | 325 | 345 |
3×185 + 1×95 | 1.6 | 1.4 | 2×0.5 | 3 | 52 | 7854 | 0.0991 | 3.5 | 375 | 390 |
3×240 + 1×120 | 1.7 | 1.6 | 2×0.5 | 3.5 | 68 | 9814 | 0.093 | 3.5 | 440 | 450 |
3×300 + 1×150 | 1.8 | 1.7 | 2×0.5 | 3.5 | 71 | 12781 | 0.093 | 3.5 | 505 | 515 |
3×400 + 1×240 | 2 | 1.7 | 2×0.5 | 3.5 | 76 | 16359 | 0.047 | 3.5 | 570 | 575 |
3+2 Core Steel Tape Armored Cable | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
3×4 + 2×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 17.5 | 855 | 4.61 | 3.5 | 34 | 45 |
3×6 + 2×4 | 0.7 | 1 | 2×0.2 | 1.5 | 18.9 | 1009 | 3.08 | 3.5 | 43 | 57 |
3×10 + 2×6 | 0.7 | 1 | 2×0.2 | 2 | 21.6 | 1461 | 1.83 | 3.5 | 60 | 77 |
3×16 + 2×10 | 0.7 | 1 | 2×0.2 | 2 | 24.6 | 1877 | 1.15 | 3.5 | 83 | 105 |
3×25 + 2×16 | 0.9 | 1 | 2×0.2 | 2 | 28.7 | 2583 | 0.727 | 3.5 | 105 | 125 |
3×35 + 2×16 | 0.9 | 1 | 2×0.2 | 2 | 30.7 | 3001 | 0.524 | 3.5 | 125 | 155 |
3×50 + 2×35 | 1 | 1 | 2×0.2 | 2 | 36.2 | 4392 | 0.387 | 3.5 | 160 | 185 |
3×70 + 2×35 | 1.1 | 1.2 | 2×0.2 | 2.5 | 40.3 | 5519 | 0.268 | 3.5 | 200 | 225 |
3×95 + 2×50 | 1.1 | 1.2 | 2×0.5 | 2.5 | 44.9 | 7543 | 0.193 | 3.5 | 245 | 270 |
3×120 + 2×70 | 1.2 | 1.2 | 2×0.5 | 2.5 | 50.3 | 9203 | 0.153 | 3.5 | 285 | 310 |
3×150 + 2×70 | 1.4 | 1.4 | 2×0.5 | 3 | 54 | 10485 | 0.124 | 3.5 | 325 | 345 |
3×185 + 2×95 | 1.6 | 1.4 | 2×0.5 | 3 | 60.2 | 13945 | 0.0991 | 3.5 | 375 | 390 |
3×240 + 2×120 | 1.7 | 1.6 | 2×0.5 | 3.5 | 67.2 | 15643 | 0.093 | 3.5 | 440 | 450 |
3×300 + 2×150 | 1.8 | 1.7 | 2×0.5 | 3.5 | 75.2 | 18204 | 0.093 | 3.5 | 505 | 515 |
IV + I Core Steel Tape Cable armatae | ||||||||||
Nom.Crucem-sectione conductor | Insulation Crassitudo | Interiorem covering Crassitudo | Ferro Tape Crassitudo | Vagina Crassitudo | Proxime.OD | Proxime Pondus | Maximilianus.DC Resistentia Conductoris (20°C) | Test intentione AC | Current Rating | |
mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km | kV/5min | In aere (A) | In solo (A) |
4×4 + 1×2.5 | 0.7 | 1 | 2×0.2 | 1.5 | 18.4 | 565 | 4.61 | 3.5 | 34 | 45 |
4×6 + 1×4 | 0.7 | 1 | 2×0.2 | 1.5 | 19.8 | 692 | 3.08 | 3.5 | 43 | 57 |
4×10 + 1×6 | 0.7 | 1 | 2×0.2 | 2 | 22.8 | 953 | 1.83 | 3.5 | 60 | 77 |
4×16 + 1×10 | 0.7 | 1 | 2×0.2 | 2 | 25.8 | 1318 | 1.15 | 3.5 | 83 | 105 |
4×25 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 30.4 | 1877 | 0.727 | 3.5 | 105 | 125 |
4×35 + 1×16 | 0.9 | 1 | 2×0.2 | 2 | 34.1 | 2324 | 0.524 | 3.5 | 125 | 155 |
4×50 + 1×25 | 1 | 1 | 2×0.2 | 2 | 38.7 | 3415 | 0.387 | 3.5 | 160 | 185 |
4×70 + 1×35 | 1.1 | 1.2 | 2×0.5 | 2.5 | 44.2 | 4432 | 0.268 | 3.5 | 200 | 225 |
4×95 + 1×50 | 1.1 | 1.2 | 2×0.5 | 2.5 | 49.8 | 5747 | 0.193 | 3.5 | 245 | 270 |
4×120 + 1×70 | 1.2 | 1.2 | 2×0.5 | 2.5 | 55.4 | 7112 | 0.153 | 3.5 | 285 | 310 |
4×150 + 1×70 | 1.4 | 1.4 | 2×0.5 | 3 | 60.1 | 8556 | 0.124 | 3.5 | 325 | 345 |
4×185 + 1×95 | 1.6 | 1.4 | 2×0.5 | 3 | 66.9 | 10510 | 0.0991 | 3.5 | 375 | 390 |
4×240 + 1×120 | 1.7 | 1.6 | 2×0.5 | 3.5 | 74.8 | 13232 | 0.093 | 3.5 | 440 | 450 |
4×300 + 1×150 | 1.8 | 1.7 | 2×0.5 | 3.5 | 78.4 | 16452 | 0.093 | 3.5 | 505 | 515 |
Promotionem extollimus et novos fructus in forum singulis annis inducimus ad Lupum Factory 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminium/Coppe Core Steel Wire PVC/XLPE Subterranea Power Armored Cable, Quo modo inceptum tuum bonum inceptum cum nostra corporatione incipiemus?Parati sumus, idoneos et impleti sumus superbia.Incipiamus novam ordinationem nostram cum fluctu novo.
Factory LupumSinis filum et filum Cuprum, Ad bona creandi plura creandi, ubertas qualitates ac solutiones ac renovationes non solum bona nostra, sed nosmetipsos renovamus ut nos ante mundum et novissimum sed maxime vitalem servemus: ut omnes clientes contenti omnibus vobis offeramus. et convalescere simul.Verus esse victor, hic incipit!