Superbi sumus in satisfacienti clienti significanti ac late acceptatione ob assiduam nostram inquisitionem qualitatis tam in mercatura quam reparatione pro qualitate optima 4 Core 50mm Swa PVC Electricity Steel Tape Armored Cable, Top qualitas, opportuna societas et sumptus infestus, omnes nos vincunt. superior fama in xxx agro non obstante intensior internationalis competition.
Superbi sumus in satisfaciendo clienti significanti et late acceptioni ob assiduam nostram inquisitionem qualitatis, tam in mercibus quam in reparatione.Sina filum cable et cable filumNostri fructus late venditi sunt Europa, USA, Russia, UK, Gallia, Australia, Medius Oriens, America Meridionalis, Africa, Asia Australis, etc. Nostrae solutiones a clientibus nostris ab omni circum terrarum orbe valde cognitae sunt.Et committitur societas nostra ad efficaciam continenter emendandi ratio administrationis nostrae ut maximize satisfactio emptoris.Nos sincero animo speramus cum clientibus nostris profectum esse ac futuram simul conciliandam creare.Grata nobis iunge negotia!

Applicationem

Xlpe insulata pvc taenia ferrata Cable ferro vaginata componitur ex puro conductore aeris, XLPE velit, armatura taenia ferro, et vagina PVC flammea retardat.Multicores funes industriales idonei sunt ad 0.6/1KV intentionis aestimationis, quae gravitati mechanicae sustinere possunt, quae adhiberi possunt ad stationes potentias, subway, cuniculos, aedificia alta ortum, magnas conatus industriales et fodiendi, agri oleum, fodinae carbones, aliaque alia. loca intensiva retinacula electrica distributa.

Construction

AVAVBA

Characteres

Ratum voltage: 0.6 / 1 kV

Maximum Conductor Temperature: sub normali (90℃), subitis (130℃) vel ambitu brevi non plus quam 5 condiciones (250℃).
Min.Ambient Temp.0℃, post institutionem et solum cum funem in certo situ
Min.Tendens Badius: 12 x cable OD pro multi core

Signa

IEC 60502-1, GB/T 12706.1

Applicationem

linearum transmissio et distributio cum 50 Hz AC aestimata intentione Uo/U 0,6/1KV et infra portabuntur;Apta ad sepeliendum impositionem, non idonea ad pipelines impositio.

Morbi laoreet

2 CoreFerro Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

2×4

0.7

1.2

2×0.2

1.8

15

433

4.61

3.5

34

45

2×6

0.7

1.2

2×0.2

1.8

16

500

3.08

3.5

43

57

2×10

0.7

1.2

2×0.2

1.8

19

673

1.83

3.5

60

77

2×16

0.7

1.4

2×0.2

1.8

21

857

1.15

3.5

83

105

2×25

0.9

1.4

2×0.2

1.8

24

1173

0.727

3.5

105

125

2×35

0.9

1.6

2×0.2

1.8

25

1449

0.524

3.5

125

155

2×50

1

1.6

2×0.2

1.8

26

1877

0.387

3.5

160

185

2×70

1.1

1.8

2×0.2

1.8

27

2454

0.268

3.5

200

225

2×95

1.1

1.8

2×0.2

1.9

30

2483

0.193

3.5

245

270

2×120

1.2

2

2×0.2

2

33

4213

0.153

3.5

285

310

2×150

1.4

2

2×0.5

2.2

38

5087

0.124

3.5

325

345

III Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×1.5

0.7

1

2×0.2

1.5

13

273

12.1

3.5

20

27

3×2.5

0.7

1

2×0.2

1.5

14

321

7.41

3.5

26

35

3×4

0.7

1.2

2×0.2

1.5

15

390

4.61

3.5

34

45

3×6

0.7

1.2

2×0.2

1.5

16

471

3.08

3.5

43

57

3×10

0.7

1.4

2×0.2

1.5

18

622

1.83

3.5

60

77

3×16

0.7

1.4

2×0.2

2

22

1005

1.15

3.5

83

105

3×25

0.9

1.6

2×0.2

2

25

1371

0.727

3.5

105

125

3×35

0.9

1.6

2×0.2

2

27

1724

0.524

3.5

125

155

3×50

1

1.8

2×0.2

2

30

2247

0.387

3.5

160

185

3×70

1.1

1.8

2×0.2

2.5

35

3023

0.268

3.5

200

225

3×95

1.1

2

2×0.5

2.5

39

3825

0.193

3.5

245

270

3×120

1.2

2

2×0.5

2.5

42

4642

0.153

3.5

285

310

3×150

1.4

2

2×0.5

3

48

5767

0.124

3.5

325

345

3× 185

1.6

2.2

2×0.5

3

51

6895

0.0991

3.5

375

390

3×240

1.7

2.2

2×0.5

3

56

8617

0.093

3.5

440

450

3×300

1.8

2.2

2×0.5

3

59

10928

0.093

3.5

505

515

3×400

2

2.2

2×0.5

3.2

61

13556

0.047

3.5

570

575

IV Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4

0.7

1

2×0.2

1.5

16

454

4.61

3.5

34

45

4×6

0.7

1

2×0.2

1.5

17

557

3.08

3.5

43

57

4×10

0.7

1

2×0.2

2

20

791

1.83

3.5

60

77

4×16

0.7

1

2×0.2

2

23

1210

1.15

3.5

83

105

4×25

0.9

1

2×0.2

2

27

1672

0.727

3.5

105

125

4×35

0.9

1

2×0.2

2

29

2127

0.524

3.5

125

155

4×50

1

1

2×0.2

2

33

2802

0.387

3.5

160

185

4×70

1.1

1.2

2×0.2

2.5

38

3785

0.268

3.5

200

225

4×95

1.1

1.2

2×0.5

2.5

42

4829

0.193

3.5

245

270

4×120

1.2

1.4

2×0.5

3

47

6033

0.153

3.5

285

310

4×150

1.4

1.4

2×0.5

3

52

7356

0.124

3.5

325

345

4× 185

1.6

1.6

2×0.5

3

56

8806

0.0991

3.5

375

390

4×240

1.7

1.6

2×0.5

3

62

11182

0.093

3.5

440

450

4×300

1.8

1.7

2×0.5

3.1

64

14176

0.093

3.5

505

515

4×400

2

1.7

2×0.5

3.5

69

17815

0.047

3.5

570

575

V Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

5×4

0.7

1

2×0.2

1.5

17.1

588

4.61

3.5

34

45

5×6

0.7

1

2×0.2

1.5

19.4

720

3.08

3.5

43

57

5×10

0.7

1

2×0.2

2

22.9

1014

1.83

3.5

60

77

5×16

0.7

1

2×0.2

2

25.8

1392

1.15

3.5

83

105

5×25

0.9

1

2×0.2

2

30.5

2002

0.727

3.5

105

125

5×35

0.9

1

2×0.2

2

33.7

2581

0.524

3.5

125

155

5×50

1

1

2×0.5

2

38.6

3722

0.387

3.5

160

185

5×70

1.1

1.2

2×0.5

2.5

43.4

4897

0.268

3.5

200

225

5×95

1.1

1.2

2×0.5

2.5

48.6

6338

0.193

3.5

245

270

5×120

1.2

1.4

2×0.5

3

54.4

7851

0.153

3.5

285

310

5×150

1.4

1.4

2×0.5

3

60.1

9661

0.124

3.5

325

345

5× 185

1.6

1.6

2×0.5

3

66.7

11770

0.0991

3.5

375

390

5×240

1.7

1.6

2×0.5

3

74.7

14900

0.093

3.5

440

450

5×300

1.8

1.7

2×0.5

3.1

83.2

18000

0.093

3.5

505

515

III + I Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 1×2.5

0.7

1

2×0.2

1.5

16

443

4.61

3.5

34

45

3×6 + 1×4

0.7

1

2×0.2

1.5

17

531

3.08

3.5

43

57

3×10 + 1×6

0.7

1

2×0.2

2

20

741

1.83

3.5

60

77

3×16 + 1×10

0.7

1

2×0.2

2

23

1135

1.15

3.5

83

105

3×25 + 1×16

0.9

1

2×0.2

2

26

1556

0.727

3.5

105

125

3×35 + 1×16

0.9

1

2×0.2

2

28

1896

0.524

3.5

125

155

3×50 + 1×25

1

1

2×0.2

2

31

2518

0.387

3.5

160

185

3×70 + 1×35

1.1

1.2

2×0.2

2.5

36

3293

0.268

3.5

200

225

3×95 + 1×50

1.1

1.2

2×0.5

2.5

40

4349

0.193

3.5

245

270

3×120 + 1×70

1.2

1.2

2×0.5

2.5

44

5365

0.153

3.5

285

310

3×150 + 1×70

1.4

1.4

2×0.5

3

49

6468

0.124

3.5

325

345

3×185 + 1×95

1.6

1.4

2×0.5

3

52

7854

0.0991

3.5

375

390

3×240 + 1×120

1.7

1.6

2×0.5

3.5

68

9814

0.093

3.5

440

450

3×300 + 1×150

1.8

1.7

2×0.5

3.5

71

12781

0.093

3.5

505

515

3×400 + 1×240

2

1.7

2×0.5

3.5

76

16359

0.047

3.5

570

575

3+2 Core Steel Tape Armored Cable

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

3×4 + 2×2.5

0.7

1

2×0.2

1.5

17.5

855

4.61

3.5

34

45

3×6 + 2×4

0.7

1

2×0.2

1.5

18.9

1009

3.08

3.5

43

57

3×10 + 2×6

0.7

1

2×0.2

2

21.6

1461

1.83

3.5

60

77

3×16 + 2×10

0.7

1

2×0.2

2

24.6

1877

1.15

3.5

83

105

3×25 + 2×16

0.9

1

2×0.2

2

28.7

2583

0.727

3.5

105

125

3×35 + 2×16

0.9

1

2×0.2

2

30.7

3001

0.524

3.5

125

155

3×50 + 2×35

1

1

2×0.2

2

36.2

4392

0.387

3.5

160

185

3×70 + 2×35

1.1

1.2

2×0.2

2.5

40.3

5519

0.268

3.5

200

225

3×95 + 2×50

1.1

1.2

2×0.5

2.5

44.9

7543

0.193

3.5

245

270

3×120 + 2×70

1.2

1.2

2×0.5

2.5

50.3

9203

0.153

3.5

285

310

3×150 + 2×70

1.4

1.4

2×0.5

3

54

10485

0.124

3.5

325

345

3×185 + 2×95

1.6

1.4

2×0.5

3

60.2

13945

0.0991

3.5

375

390

3×240 + 2×120

1.7

1.6

2×0.5

3.5

67.2

15643

0.093

3.5

440

450

3×300 + 2×150

1.8

1.7

2×0.5

3.5

75.2

18204

0.093

3.5

505

515

IV + I Core Steel Tape Cable armatae

Nom.Crucem-sectione conductor

Insulation Crassitudo

Interiorem covering Crassitudo

Ferro Tape Crassitudo

Vagina Crassitudo

Proxime.OD

Proxime Pondus

Maximilianus.DC Resistentia Conductoris (20°C)

Test intentione AC

Current Rating

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

kV/5min

In aere (A)

In solo (A)

4×4 + 1×2.5

0.7

1

2×0.2

1.5

18.4

565

4.61

3.5

34

45

4×6 + 1×4

0.7

1

2×0.2

1.5

19.8

692

3.08

3.5

43

57

4×10 + 1×6

0.7

1

2×0.2

2

22.8

953

1.83

3.5

60

77

4×16 + 1×10

0.7

1

2×0.2

2

25.8

1318

1.15

3.5

83

105

4×25 + 1×16

0.9

1

2×0.2

2

30.4

1877

0.727

3.5

105

125

4×35 + 1×16

0.9

1

2×0.2

2

34.1

2324

0.524

3.5

125

155

4×50 + 1×25

1

1

2×0.2

2

38.7

3415

0.387

3.5

160

185

4×70 + 1×35

1.1

1.2

2×0.5

2.5

44.2

4432

0.268

3.5

200

225

4×95 + 1×50

1.1

1.2

2×0.5

2.5

49.8

5747

0.193

3.5

245

270

4×120 + 1×70

1.2

1.2

2×0.5

2.5

55.4

7112

0.153

3.5

285

310

4×150 + 1×70

1.4

1.4

2×0.5

3

60.1

8556

0.124

3.5

325

345

4×185 + 1×95

1.6

1.4

2×0.5

3

66.9

10510

0.0991

3.5

375

390

4×240 + 1×120

1.7

1.6

2×0.5

3.5

74.8

13232

0.093

3.5

440

450

4×300 + 1×150

1.8

1.7

2×0.5

3.5

78.4

16452

0.093

3.5

505

515

Superbi sumus in satisfacienti clienti significanti ac late acceptatione ob assiduam nostram inquisitionem qualitatis tam in mercatura quam reparatione pro qualitate optima 4 Core 50mm Swa PVC Electricity Steel Tape Armored Cable, Top qualitas, opportuna societas et sumptus infestus, omnes nos vincunt. superior fama in xxx agro non obstante intensior internationalis competition.
Qualis optimusSina filum cable et cable filumNostri fructus late venditi sunt Europa, USA, Russia, UK, Gallia, Australia, Medius Oriens, America Meridionalis, Africa, Asia Australis, etc. Nostrae solutiones a clientibus nostris ab omni circum terrarum orbe valde cognitae sunt.Et committitur societas nostra ad efficaciam continenter emendandi ratio administrationis nostrae ut maximize satisfactio emptoris.Nos sincero animo speramus cum clientibus nostris profectum esse ac futuram simul conciliandam creare.Grata nobis iunge negotia!


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis